Owner`s manual
R
AR-200S RS-232C Reference -
13
= RE Start Recording
Function: Start recording
Syntax: stxRE;
Note: When using the RE command, you must first use the RM command to put the
unit in Record ready mode. To stop recording, use the ST command.
Recording starts when audio higher than the trigger level is input.
the following four types of trigger recording setteings are available.
OFF: Trigger recording is not performed.
LOW: Recording starts when audio higher than -45dB.
MID: Recording starts when audio higher than -36dB.
HIGH: Recording starts when audio higher than -27dB.
= RM Record Ready Mode
Function: Record ready mode
Syntax: stxRM: a, d , c, d, e, f, g;
a Phrase number
b RDAC-Grade
0 Announce
1 Long 2
2 Long 1
3 Standard
4 High
5 S-High
c RDAC-Mode
0 Linear
1 Mode1
2 Mode2
3 Mode3
4 H – Linear
d Recording type
0 Mono
1 Stereo
e Trigger recording
0 Off
1 Low
2 Mid
3 High
f Reserved (0)
g Reserved (0)
Example) RM: A1,3,2,1,0,0,0;
This sets as follows; phrase “A0001”, RDAC-Grade “STANDARD”, RDAC-Mode
“MODE2”, Recording type “STEREO”, Trigger recording “OFF”.
Caution: It is not possible to specify a phrase number which has already been recorded.
If you wish to re-record a phrase that is already recorded, use the PD command to
delete the phrase, and then transmit the RM command.
The AR-200S cannot respond to this command during crossfades, repeats, or
intervals.