User`s manual

4-7 Changing How the Media Heating System Operates
Chapter 4 Feature Reference
97
Description
This makes the temperature setting for the media heating system when is dark.
"MENU" performs heating to the preset temperature at all times, without lowering the temperature when is
dark.
A setting of "35˚C" lowers the media heating system to a fixed temperature (35˚C) when
is dark. This tempera-
ture setting cannot be changed. When the temperature is set at less than 35˚C, however, the temperature is maintained
at the set value.
"OFF" switches off the media heating system when
is dark.
Default Setting
[PREHEATING]: 35˚C
Switching the Blower Fan On and Off
Procedure
Hold down and press .
Press .
Press .
Use
to make the setting.
Press
to enable the setting.
Press .
Press
to go back to the original screen.
Description
The blower fan hastens ink-drying by blowing moving air onto the media on the drying heater. The force of the moving
air cannot be adjusted.
When this is set to "ON" (the default setting), the fan starts when media is loaded and the loading lever is engaged.
Note, however, that when [DRYER] is set to "OFF," no operation starts when the loading lever is engaged.
When this is set to "OFF," the blower fan does not operate, regardless of the [DRYER] setting or the state of the loading
lever.
Default Setting
[BLOWER FAN]: ON
W 2600 mm
SETUP SHEET
HEATER MENU
FEED FOR DRY
HEATER MENU
BLOWER FAN
BLOWER FAN
ON
OFF