Owner`s manual
4
VM-C7200/C7100 Newly Added Functions
Example 3
• If AES/EBU device does not output the word clock
Connect the output of the AES/EBU device to the INPUT A
of the 1st AE-7000. In this case, please set the clock source on
the AE-7000, and then the master clock on the VM-7000.
Clock source on the 1st AE-7000:............................... INPUT A
Clock source on the 2nd and later AE-7000’s:................R-BUS
Master clock on the VM-7000:
...........................R-BUS which the 1st AE-7000 is connected to
* Please refer to AE-7000 Owner’s Manual p. 5 “Clock source
select” and VM-C7200/C7100 Owner’s Manual p. 31 “About
Digital Connections and the Master Clock.”
* If the system of the VM-C7200/C7100 is version 1.0 or earlier,
“DIF-AT” is displayed in the R-BUS CONFIG page even
though the AE-7000 is connected. This cause no problem for
the operation. With the VM-C7200/C7100 version 1.10 or
later, you can set the AE-7000 with the R-BUS CONFIG
page.
If the system software of the
VM-C7200/C7100 is Ver.1.10 or later
If the system software of the VM-C7200/C7100 is version
1.10 or later, following functions are supported.
AE-7000 Clock source setting
You can set up the AE-7000’s clock source with the VM-
C7200/C7100 console.
1. Hold down [SHIFT], and press [SYSTEM] (PROJECT).
SYSTEM menu appears in the display.
2. Select “SYSTEM CONFIG” and go to “R-BUS (1/2/3)”
page.
3. Following page appears in the display.
fig.ae_70
4. Select a desired source with V1 knob (CLOCK
SOURCE).
5. Press [F1] (SET) and the clock source you selected is
activated.
Digital Out settings
1. Hold down [SHIFT], and press [SYSTEM] (PROJECT).
SYSTEM menu appears in the display.
2. Select “SYSTEM CONFIG” and go to “R-BUS (1/2/3)”
page.
3. Select the TYPE with V3 knob [TYPE1/TYPE2].
TYPE1: Broadcasting studio
TYPE2: Consumer digital audio
4. Press [F3] (SET) and the setting is activated.
5. If you set [F4] (COPY PROTECT) to ON, SCMS turns on
and you can restrict the digital copy of the output signal.
* If the TYPE is set to TYPE1 (Broadcasting studio), COPY
PROTECT setting is invalid.
* If digital signal is connected into the digital input of the
AE-7000, status is shown in the middle of the display.
How to connect the VSR-880 and
the VM-7000 series
To connect the VSR-880 and the VM-7200/7100 via R-BUS,
VM-24E I/O Expansion Board (sold separately) is needed.
By installing the VM-24E to the VM-7200/7100 processor,
you can connect up to three VSR-880’s.
* Refer to the VM-7200/7100 Owner’s Manual p. 14
“Installing R-BUS (RMDB2) Connectors (VM-24E).”
Connection
Connect the VSR-880 and the VM-7200/7100 with the R-BUS
cable (RBC-1 or RBC-05; separately sold).
* Refer to the VSR-880 Owner’s Manual p. 140 “Synchronized
operation of two or more VSR-880 units.”
Booting up
Turn the power on the VSR-880 first, then VM-7100/7200
processor, and finally VM-C7100/7200 console.