Owner`s manual

2
VM-C7200/C7100 Newly Added Functions
ADA-7000 setting
Check if the clock source on the ADA-7000 is set to R-BUS.
When the ADA-7000 is booted up, the clock source is set to
R-BUS. If you connect multiple ADA-7000, set the clock
source on all ADA-7000 to R-BUS.
* Refer to ADA-7000 Owner’s Manual p. 6 “Clock source.”
VM-7000 setting
Set the master clock of the VM-7200/7100 to INTERNAL as
follows.
1. Hold down [SHIFT], and press [SYSTEM] (PROJECT).
2. Press [DOWN] cursor, then press [F1] (DIGITAL I/O).
3. Select “WORD CLOCK SOURCE,” and set it to
“INTERNAL” with V1 knob, then press [F1] (SET) to
activate the result.
* Refer to the VM-C7200/C7100 Owner’s Manual p. 32
“Checking the overall system.”
* If you set the clock source differently, please refer to the ADA-
7000 Owner’s Manual p. 6 “Clock source” and the VM-
C7200/C7100 Owner’s Manual p. 31 “About Digital
Connections and the Master Clock.”
* If the system of the VM-C7200/C7100 is version 1.0 or earlier,
“DIF-AT” is displayed in the R-BUS CONFIG page even
though the ADA-7000 is connected. This cause no problem for
the operation. With the VM-C7200/C7100 version 1.10 or
later, you can set the ADA-7000 with the R-BUS CONFIG
page.
* VM-7000 is not accommodated with 96.0 kHz sample rate.
96.0 kHz sample rate capability on the ADA-7000 is for the
future devices.
If the system software of the
VM-C7200/C7100 is Ver.1.10 or later
If the system software of the VM-C7200/C7100 is version
1.10 or later, following functions are supported.
ADA-7000 Clock source setting
You can set up the ADA-7000’s clock source with the
VM-C7200/C7100 console.
1. Hold down [SHIFT], and press [SYSTEM] (PROJECT).
SYSTEM menu appears in the display.
2. Select “SYSTEM CONFIG” and go to “R-BUS 1(/2/3)”
page.
3. Following page appears in the display.
fig.ada_70
* If the above menu does not appear in the “R-BUS 1(/2/3)”
page of “SYSTEM CONFIG” menu, please turn off the power
of whole system, check the R-BUS connection and turn on
again.
4. Select a desired source with V1 knob (CLOCK
SOURCE).
5. Press [F1] (SET) and the clock source you selected is
activated.
6. If you select “INTERNAL” for the clock source, set the
sampling rate with V3 knob (SAMPLING RATE).
7. Press [F3] (SET) and the sampling rate you selected is
activated.
Front Panel Control
In the R-BUS 1(/2/3) page, you can prohibit the ADA-7000’s
panel operation.
1. Hold down [SHIFT], and press [SYSTEM] (PROJECT).
SYSTEM menu appears in the display.
2. Select “SYSTEM CONFIG” and go to “R-BUS 1(/2/3)”
page.
3. Press [F5] (FRONT PANEL CONTROL).
Highlight ON: Panel control enabled
Normal ON: Panel control invalid
Remote control of the gain and phantom
power
You can control the gain setting and phantom power on/off
with the VM-C7200/C7100 console.
1. Press [MULTI IN 1-24] in the “SECTION” block.
2. Press [PREAMP GAIN] in the “PARAM VIEW on Fader”
block.