GLOBE FLOWCELL Operating Manual Rola-Chem Flowcell PN 550182 4/01/2013 page: 1 of 8
Table of Contents Section title 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 1.0 Page Safety Instructions Description Installation Use of Manifold Maintenance Trouble Shooting Parts List Warranty and Service 2 2 3 5 5 5 6 7 Safety Instruction See controller manual for additional safety instructions. A- WARNING: Do not shut down circulating and control system immediately after using pool, spa or hot tub. Systems must operate until water chemistry is stable.
pH PROBE ORP PROBE PROBE FITTING FLOW SWITCH LEADS FLOAT (INSIDE CELL) SHUT-OFF VALVE FILTER & SHUT-OFF VALVE (OPTIONAL) RECOMMENDED GROUNDING STUD BOTTOM VIEW 3.0 Installation 1. Mount Manifold: Pre-mark hole locations for manifold mounting screws using the manifold. The manifold should not be above the controller unit or other equipment or electrical devices. Manifold holes will accept #10 screws. 2. Install pH and ORP Probes: Note: standard probes have platinum tips.
3. Install Manifold Connections to the Pool Water System Turn off the pool's pump system during this procedure. Check that sufficient tubing (supplied) is available for connecting Manifold prior to drilling holes. Additional tubing may be obtained –see parts list for part numbers. Do not exceed a total of 40' of tubing. Select installation points in the Pool Circulation System for the fitting that will provide flow into the Manifold.
4.0 Use of Manifold 1. Manifold Inlet and Outlet Valves: 1.1 Adjust flow through Manifold. Turn left Valve to full on position. Close the right Valve and then open it until the Float rises to the top of its chamber. The Float will not rise if flow is not sufficient or backwards. 1.2 Removing Probes. The Valves allow the operator to remove Probes without shutting down the pool pump. Close both left and right Valves before loosening the Probe fittings.
7.0 Parts List 1 4 2 3.3 550591 FILTER KIT (NOT TO SCALE) 3.2 3.1 4 550592 FILTER KIT (NOT TO SCALE) 3.4 3.6 PART NO. DESCRIPTION 1 550136 ORP PROBE- HEAVY DUTY, 8 FT CABLE 1 550209 ORP PROBE- HEAVY DUTY, 3 FT CABLE 1 550201 ORP PROBE- GOLD TIP, 8 FT CABLE 2 550135 pH PROBE- HEAVY DUTY, 8 FT CABLE 2 550208 pH PROBE- HEAVY DUTY, 3 FT CABLE 3 550180 FLOWCELL ASSEMBLY, 3/8 TUBE (INCLUDES 3.1 THRU 3.6) 3.1 550181 FLOWCELL, CLEAR GLOBE 3.2 550183 FLOW SWITCH 3.
8.0 Warranty and Service8.1 Limited Warranty Rola-Chem Corporation warrants the original purchaser that this unit is free from manufacturing defects in material and workmanship from the date of the original purchase for one (1) year. If this unit fails within the one (1) year period, it will be repaired or replaced at Rola-Chem’s option, at no charge, when returned to Rola-Chem Corporation with proof of purchase receipt.