Specification Sheet

www.rohlhome.com
Consult your local ROHL showroom for additional information and specications. For complete warranty details and a list of showrooms, go to www.rohlhome.com.
INSTALLATION INSTRUCTIONS
VERTICAL
STUD
PLUMBERS TAPE
TO VALVE
Pre-assemble fittings before attaching to valve. Attach the “COLD” INLET to COLD SUPPLY and “HOT”
INLET to HOT SUPPLY using copper supply lines.
IMPORTANT: Thoroughly flush supply lines to remove any debris prior to installation to prevent damage
and malfunction of thermostatic cartridge.
ATTENTION: Use plumbers tape or thread sealant to all threaded port joints and attach to valve. All
soldering/brazing of fittings shall be performed a minimum of 4” away from valve.
WARNING: DO NOT APPLY HEAT DIRECTLY TO THE VALVE AS THIS MAY DAMAGE RUBBER & PLASTIC SEALS
AND WILL VOID WARRANTY.
Turn on water supplies to valve and check for leaks.
Once the desired location has been determined, install a cross support beam to wall studs.
Ensure to level the valve and secure to the cross support. The valve should be level horizontally,
vertically, and parallel to finished wall.
Placement of valve and cross support within the wall shall be determined by the MIN/MAX limits shown
on MUDGUARD. For complete detailed valve dimensions see ROUGH-IN DIMENSIONS.
4” MIN.
MOUNT SCREWS [6X]
(not provided)
CROSS
SUPPORT
WATER CONNECTIONS
ROUGH IN VALVE TO FRAME
COLD
SUPPLY
HOT
SUPPLY
Attach OUTLET (1) to the shower head and outlets (2) and (3) to any optional devices, such as hand
shower or body sprays. Any outlet not being used must be plugged.
OUTLETS
(1) (2) (3)
Carefully install the cartridge
back into the housing body
and tighten nut to 10 ft-lbs
(13,56 nm).
ATTENTION: Ensure the
INDICATOR NOTCH on
cartridge and GREEN LINE on stem
are orientated at the 12 O’Clock
position. The Temperature stop
must be in the 6 O’Clock position.
Fully open temporary shutoff
screws and check for leaks.
Check operation of flow. If
improved, proceed to
reinstall extensions, trim &
plate; otherwise, CHECK
VALVES.
THERMOSTATIC CARTRIDGE
Carefully remove the trim and plate and place in a safe location for the time being.
Use a flat head screwdriver to shut off the water supply to the cartridge by turning the temporary shutoff
screws clockwise until screw stops. Ensure to close both the hot and cold sides of the water supplies.
Remove extensions to gain access to the cartridge nut. Unscrew the cartridge nut using a 11/16”
adjustable wrench, if possible.
Gently pull the cartridge out of the housing body (rotating cartridge while pulling may assist in
removal).
Clean the cartridge by rinsing it under running water to remove any possible debris.
Wipe cartridge and rough housing clean and apply a thin film of NON-PETROLEUM GREASE to o-rings on
cartridge.
NOTE: Do NOT use oil based lubricants as this may cause the o-rings to dry out over time and crack.
MAINTENANCE
TOP VIEW
INDICATOR
FRONT VIEW
12 O’Clock
Position
6 O’Clock
Position
120º
MAX
100º
80º
MIN
7 3/4”
3 5/8”
3 3/8”
CUT OUT FOR TILE
3”MAX. x 6 1/2”MAX.