Specification Sheet

www.rohlhome.com
Consult your local ROHL showroom for additional information and specications. For complete warranty details and a list of showrooms, go to www.rohlhome.com.
INSTALLATION INSTRUCTIONS
The valve is designed with two outlets for ease of installation, but are not intended to be used
concurrently with each other. Using both outlets will reduce the performance of the valve.
WARNING: IF THIS VALVE IS INSTALLED UPSIDE-DOWN A REVERSE CARTRIDGE IS NOT AVAILABLE.
CONSEQUENTLY, VALVE MUST BE REMOVED AND REINSTALLED RIGHT-SIDE UP.
Female 1/2” NPT inlets and outlets
Factory temperature setting = 100°F (38°C)
Temperature range = 52° to 118°F (11°-48°C)
Temperature hot supply = 149° to 180°F (65°-82°C)
Temperature cold supply = 50° to 72°F (10°-22°C)
Temperature stability = ±32°F (0°C)
Recommended supply pressure = 20 to 80 psi (1,38-5,52 bar)
Recommended hot water supply temperature = 120° to 140°F (48°-60°C)
Operating pressures between hot and cold supplies should vary no more than 30 psi (2,07 bar).
If water pressure exceeds 70 psi (4,83 bar), install a pressure reducing valve.
Ensure the mixing valve is in compliance with local plumbing codes when setting the temperature on
the water heater.
It is the installer’s responsibility to verify correct temperature setting to prevent any risk of scalding prior to
consumer use.
VALVE SPECIFICATIONS
VALVE
MOUNTING
TABS (X2)
HOT SUPPLY
CONNECTION
COLD SUPPLY
CONNECTION
Tighten check valves to 10 ft-lbs (13,56 nm).
Reinstate water supply from upstream and check
for leaks.
Check operation of flow. If improved, proceed to
reinstall extensions, trim, & plate; otherwise, see
PARTS BREAKOUT for any replacement parts
needed.
CHECK VALVES
Shut off water supply at main or upstream from valve body.
Remove check valve with a 5/8” (16mm) socket wrench from the body.
Clean check valve by rinsing it under running water to remove any possible debris.
Wipe check valve and housing seat clean and apply a thin film of NON-PETROLEUM GREASE to o-rings.
NOTE: Do NOT use oil based lubricants as this may cause o-rings to dry out over time and crack.
MAINTENANCE (continued)
10
14
4
3
13
2
1
12
15
9
5
7
8
6
11.1
11.2
11.3
13
16
ITEM
PART
DESCRIPTION
QTY.
1 10333
C-WASHER STABILIZER
1
2 10334
M24X1.0 EXTENSION
1
3 10349
NUT CAP FOR 3WAY DIVERTER
1
4a 11297
CARTRIDGE, DIVERTER 3 POSITION
NON-SHARED (R1050BD)
1
5 10625
CARTRIDGE VALVE, THERMO
1
6 11318
RETAINER NUT FOR THERM CARTRIDGE
1
7 11319
CARTRIDGE RETAINER SLEEVE, THERM
1
8 11320
SAFETY AND MECHANICAL STOP
1
9
2-130
SHUTOFF NUT, MINI THERMO
2
10
2-132
BRAZED THERMO W/ DIVERTER VALVE 1
11
3-056
EXTENSION KIT, M24 - 20PT - STABILIZER
1
11.1
10332
20 POINT BROACH EXTENSION
1
11.2
10334
M24X1.0 EXTENSION
1
11.3
10333
C-WASHER STABILIZER
1
12 30230
STEM ADAPTOR FOR PERRIN & ROWE
2
13 30232
EXTENSION SLEEVE,
M24 INT./EXT. THERM W/ DIVERTER
1
14 30233
20 POINT BROACH EXTENSION
1
15
30238
COUNTRY ADAPTOR
2
ITEM
PART
DESCRIPTION
QTY.
11417
CARTRIDGE, SHARED DIVERTER (R1055BD)
*
14b
*30238
CAPS TO CLOSE UNUSED
OUTLETS INCLUDED
7 3/4”
3 5/8”
3 3/8”
CUT OUT FOR TILE
3”MAX. x 6 1/2”MAX.