Oscilloscope portfolio
R&S® family RTH1000 RTC1000 RTB2000 RTM3000 RTA4000 RTE1000 RTO2000
Vertical
Bandwidth 60/100/200/350/500MHz
1)
50/70/100/200/300MHz
1)
70/100//200/300MHz
1)
100/200/350/500MHz/1GHz
1)
200/350/500MHz/1GHz
1)
200/350/500 MHz/1/1.5/2GHz
1)
600 MHz/1/2/3/4/6GHz
1)
Number of channels 2 plus DMM/4 2 2/4 2/4 4 2/4 2/4 (only 4 channels in 4GHz and 6GHz model)
V/div 1MΩ 2mV to 100V 1mV to 10V 1mV to 5V 500µV to 10V 500µV to 10V 500µV to 10V 1mV to 10V (500μV to 10V)
2)
V/div 50Ω – 500µV to 1V 500µV to 1V 500µV to 5V 1mV to 1V (500μV to 1V)
2)
Horizontal
Sampling rate 1.25Gsample/s per channel
(4-channel model);
2.5Gsample/s per channel
(2-channel model);
5Gsample/s (all channels interleaved)
1Gsample/s per channel
2Gsample/s (2 channels
interleaved)
1.25Gsample/s per channel;
2.5Gsample/s (2 channels
interleaved)
2.5Gsample/s per channel;
5Gsample/s
(2 channels interleaved)
2.5Gsample/s per channel;
5Gsample/s (2 channels interleaved)
5Gsample/s per channel 10Gsample/s per channel;
20Gsample/s (2 channels interleaved in 4GHz and 6GHz model)
Max. memory
(per channel/1 channel
active)
125ksample (4-channel model);
250ksample (2-channel model);
500ksample (50Msample in segment-
ed memory mode
2
)
1Msample; 2Msample 10Msample; 20Msample
(160Msample in segmented mem-
ory mode
2)
)
40Msample;
80Msample (400Msample
in segmented memory mode
2)
)
100Msample;
200Msample (1Gsample
in segmented memory mode
2)
)
50 Msample/200 Msample standard: 50Msample/200Msample;
max. upgrade: 1Gsample/2Gsample
Segmented memory option – option option standard standard
Acquisition rate 50 000 waveforms/s 10 000 waveforms/s 50 000 waveforms/s 64 000 waveforms/s
(700 000 waveforms/s in
fast segmented memory mode
2)
)
64 000 waveforms/s
(700 000 waveforms/s in
fast segmented memory mode
2)
)
1 000 000 waveforms/s
(2 000 000 waveforms/s in
ultra- segmented memory mode)
1 000 000 waveforms/s
(3 000 000 waveforms/s in ultra-segmented memory mode)
Trigger
Options advanced, digital trigger
(14 trigger types)
2)
elementary (5 trigger types) basic (6 trigger types) basic (7 trigger types) basic (7 trigger types) advanced, digital trigger (13 trigger types) advanced (includes zone trigger), digital trigger (14 trigger types)
2)
Mixed signal option
No. of digital channels
1)
8 8 16 16 16 16 16
Sampling rate of digital
channels
1.25Gsample/s 1Gsample/s 1.25Gsample/s two logic probes:
2.5 Gsample/s on each channel;
one logic probe:
5 Gsample/s on each channel
two logic probes:
2.5 Gsample/s on each channel;
one logic probe:
5 Gsample/s on each channel
5Gsample/s 5Gsample/s
Max. memory of digital
channels
125ksample 1Msample 10Msample 80Msample 200 Msample 100Msample 200Msample
Analysis
Cursor meas. types 4 13 4 4 4 3 3
Stand. meas. functions 35 31 31 31 31 47 47
Mask test elementary (tolerance mask around the signal) elementary (tolerance mask around the
signal)
advanced (freely configurable, hardware-based)
Mathematics elementary basic (math on math) basic (math on math) advanced (formula editor) advanced (formula editor)
Serial protocols triggering
and decoding
1)
I
2
C, SPI, UART/RS-232/RS-422/ RS-485,
CAN/LIN, CAN-FD, SENT (6)
I
2
C, SPI, UART/RS-232/ RS-422/RS-485, CAN/LIN (4) I
2
C, SPI, UART/RS-232/
RS-422/RS-485, CAN/LIN, I
2
S,
MIL-STD-1553, ARINC 429 (7)
I
2
C, SPI, UART/RS-232/RS-422/RS-485,
CAN/LIN, I
2
S, MIL-STD-1553, ARINC 429 (7)
I
2
C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN,
I
2
S, MIL-STD-1553, ARINC 429, FlexRay™,
CAN-FD, USB 2.0/HSIC, Ethernet, Manchester,
NRZ, SENT, SpaceWire, CXPI, USB Power
Delivery, automotive Ethernet 100BASE-T1 (18)
I
2
C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN, I
2
S, MIL-STD-1553,
ARINC 429, FlexRay™, CAN-FD, MIPI RFFE, USB2.0/HSIC, MDIO,
8b 10b, Ethernet, Manchester, NRZ, SENT, MIPI D-PHY, SpaceWire,
MIPI M-PHY/ UniPro, CXPI, USB3.1 Gen1, PCIe 1.1/2.0, USB Power
Delivery, automotive Ethernet 100BASE-T1 (26)
Display functions data logger – – – – histogram, trend, track
2)
Applications
1)
high resolution frequency counter, ad-
vanced spectrum analysis, harmonics
analysis
– digital voltmeter (DVM) power, digital voltmeter
(DVM), spectrum analysis
and spectrogram
power, digital voltmeter (DVM), spectrum
analysis and spectrogram
R&S®RTM applications
+
16-bit high definition mode, advanced spectrum
analysis and spectrogram
R&S®RTE applications
+
jitter, clock data recovery, I/Qdata, RF analysis
Compliance testing
1)
– – – – – – various options available, for details see data sheet (PD3607.2684.22)
Display and operation
Size and resolution 7", color, 800×480 pixel 6.5", color, 640×480 pixel 10.1", color, 1280×800 pixel 10.1", color, 1280×800 pixel 10.1", color, 1280×800 pixel 10.4", color, 1024×768 pixel 12.1", color, 1280×800 pixel
Operation optimized for touchscreen operation,
parallel button operation
optimized for fast button
operation
optimized for touchscreen operation, parallel button operation optimized for touchscreen operation, parallel button operation
General data
Size in mm (W×H×D) 201×293×74 285×175×140 403×189×142 403×189×142 403×189×142 427×249×204 427×249×204
Weight in kg 2.4 1.7 2.5 3.3 3.3 8.6 9.6
Battery lithium-ion, > 4h – – – – – –
1)
Upgradeable.
2)
Requires an option.
RTM3000_bro_en_5214-9144-12_v0300.indd 16 30.11.2017 13:37:38