Definitions  
General 
Product data applies under the following conditions: 
  Three hours storage at ambient temperature followed by 30 minutes warm-up operation 
  Specified environmental conditions met 
  Recommended calibration interval adhered to 
  All internal automatic adjustments performed, if applicable 
Specifications with limits 
Represent warranted product performance by means of a range of values for the specified parameter. These specifications are 
marked with limiting symbols such as <, ≤, >, ≥, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by 
testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift 
and aging, if applicable. 
Specifications without limits 
Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent 
values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is 
ensured by design. 
Typical data (typ.) 
Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a 
range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the 
mean value. 
Nominal values (nom.) 
Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to 
typical data, a statistical evaluation does not take place and the parameter is not tested during production. 
Measured values (meas.) 
Characterize expected product performance by means of measurement results gained from individual samples.  
Uncertainties 
Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been 
calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account 
environmental conditions, aging, wear and tear. 
Device settings and GUI parameters are indicated as follows: “parameter: value”. 
Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz. 
In line with the 3GPP/3GPP2 standard, chip rates are specified in Mcps (million chips per second), whereas bit rates and symbol rates 
are specified in Mbps (million bits per second), kbps (thousand bits per second) or ksps (thousand symbols per second), and sample 
rates are specified in Msample/s (million samples per second). Mcps, Mbps, kbps, ksps and Msample/s are not SI units. 