Command AF6
command function
AF6 <AF-frequency range F3> query of AF-frequency 400 Hz
The command AF6 reads the actual AM frequency (F3) in the BEACON mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AF6 <CR>
af6 <CR>
e.g. 400.0Hz <CR/LF>
e.g. 400.0Hz <CR/LF>
Command AF7
command Funktion
AF7 <AF-Frequenz ID> query of AF-frequency ID
The command AF7 reads the actual AF frequency (ID) in the BEACON mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AF7 <CR>
af7 <CR>
e.g. 1020.0Hz <CR/LF>