User manual
VOR/ILS Analyzer EVS200
0796.1800.02 E-8 51
Chapter 3: Operation
Command AM7
Kommando Funktion
AM6 <AM-modulation depth ID> query of AM-modulation depth ID
The command AM7 reads the actual AM-modulation depth (ID) in the BEACON mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AM7 <CR>
am7 <CR>
e.g. 10.2% <CR/LF>
e.g. 10.2% <CR/LF>
Command AF4
command function
AF4 <AF-frequency range F1> query of AF-frequency 3000 Hz
The command AF4 reads the actual AF frequency (F1) in the BEACON mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AF4 <CR>
af4 <CR>
e.g. 3000.0Hz <CR/LF>
e.g. 3000.0Hz <CR/LF>
Command AF5
command function
AF5 <AF-frequency range F2> query of AF-frequency 1300 Hz
The command AF5 reads the actual AF frequency (F2) in the BEACON mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AF5 <CR>
af5 <CR>
e.g. 1300.0Hz <CR/LF>
e.g. 1300.0Hz <CR/LF>