Command BE
command funcion
BE <Bearing Angle> bearing angle query
The command BE reads the actual bearing angle (indicated in degree) in the VOR mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
BE <CR>
be <CR>
e.g. 299.97DEG <CR/LF>
e.g. 299.97DEG <CR/LF>
Command AM0
command function
AM0 <AM-modulation depth (30 Hz)> query of AM-modulation depth (30 Hz)
The command AM0 reads the actual AM-modulation depth (30 Hz) in the VOR mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AM0 <CR>
am0 <CR>
e.g. 30.1% <CR/LF>
e.g. 30.1% <CR/LF>
Command AM1
command function
AM1 <AM-modulation depth (9960 Hz)>
query of AM-modulation depth (9960 Hz)
The command AM1 reads the actual AM-modulation depth (9960 Hz) in the VOR mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AM1 <CR>
am1 <CR>
e.g. 30.1% <CR/LF>
e.g. 30.1% <CR/LF>