User manual

VOR/ILS Analyzer EVS200
0796.1800.02 E-8 37
Chapter 3: Operation
Command AM2
command function
AM2 <AM modulation depth (90 Hz)> query of AM modulation depth (90 Hz)
The command AM2 reads the actual AM modulation depth (90 Hz) in the ILS mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
AM2 <CR>
am2 <CR>
e.g. 50% <CR/LF>
e.g. 50% <CR/LF>
Command AM3
command function
AM3 <AM modulation depth (150 Hz)> query of AM modulation depth (150 Hz)
The command AM3 reads the actual AM modulation depth (150 Hz) in the ILS mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
Query:
AM3 <CR>
am3 <CR>
e.g. 29.9% <CR/LF>
e.g. 29.9% <CR/LF>
Command PH
command function
PH <Phase 90/150 Hz> query of Phase angle 90/150 Hz
The command PH reads the actual PHI value between 90 Hz and 150 Hz in the ILS mode.
Example:
command from the controller
response of the VOR/ILS Analyzer EVS200
query:
PH <CR>
ph <CR>
e.g. 119.9DEG <CR/LF>
e.g. 119.9DEG <CR/LF>