Datasheet
Version 05.00, December 2017
Rohde & Schwarz R&S
®
RTM Oscilloscope 25
R&S
®
RTM-K18
Spectrum analysis and spectrogram
General
additional displays
spectrum traces and/or spectrogram
Spectrum
sources
R&S
®
RTM3002
channel 1, channel 2
R&S
®
RTM3004
channel 1, channel 2, channel 3,
channel 4
setup parameters
center frequency, frequency span,
automatic RBW, resolution bandwidth,
gate position, gate width, vertical scale,
vertical position, spectrum mode
scaling
dBm, dBV, V (RMS)
span
1 kHz to 1.25 GHz
resolution bandwidth
span/10 ≥ RBW ≥ span/1000
windows
flat top, Hanning, Hamming, Blackman,
rectangular
trace types
normal, max. hold, min. hold, average
spectrum mode
optimized for dynamic range of frequency
domain (disables time domain for the
same channel)
Spectrogram
color
rainbow, temp. color, monochrome
Marker
peak marker search
standard search
parameter: min. level
advanced search
parameter: min. level, excursion,
maximum width, distance to next peak
reference marker
selection via index or frequency range
markers on peak
up to 100 markers
sources
any spectrum trace
table
frequency and magnitude, absolute or
relative to reference marker
marker result display
indicated at wave form: level, frequency
Cursor
measurements on spectrum traces
level, frequency, level and frequency,
V-marker
additional actions for cursor
coupling of cursors, set to trace, set to
screen, track scaling, set next and
previous peak
Spectrogram measurements
two time cursor
t1, t2, delta t, total time, relative time
between segments