Datasheet
Version 20.00, July 2019
42 Rohde & Schwarz R&S
®
RTE Oscilloscope
Ordering information
Designation
Type
Order No.
Base unit (including standard accessories: R&S
®
RTE-ZP10 500 MHz passive probe per channel, accessories bag, quick start guide,
CD with manual, power cord)
Oscilloscope
200 MHz, 5 Gsample/s, 50/100 Msample, 2 channels
R&S
®
RTE1022
1326.2000.22
200 MHz, 5 Gsample/s, 50/200 Msample, 4 channels
R&S
®
RTE1024
1326.2000.24
350 MHz, 5 Gsample/s, 50/100 Msample, 2 channels
R&S
®
RTE1032
1326.2000.32
350 MHz, 5 Gsample/s, 50/200 Msample, 4 channels
R&S
®
RTE1034
1326.2000.34
500 MHz, 5 Gsample/s, 50/100 Msample, 2 channels
R&S
®
RTE1052
1326.2000.52
500 MHz, 5 Gsample/s, 50/200 Msample, 4 channels
R&S
®
RTE1054
1326.2000.54
1 GHz, 5 Gsample/s, 50/100 Msample, 2 channels
R&S
®
RTE1102
1326.2000.62
1 GHz, 5 Gsample/s, 50/200 Msample, 4 channels
R&S
®
RTE1104
1326.2000.64
1.5 GHz, 5 Gsample/s, 50/100 Msample, 2 channels
R&S
®
RTE1152
1326.2000.72
1.5 GHz, 5 Gsample/s, 50/200 Msample, 4 channels
R&S
®
RTE1154
1326.2000.74
2 GHz, 5 Gsample/s, 50/100 Msample, 2 channels
R&S
®
RTE1202
1326.2000.82
2 GHz, 5 Gsample/s, 50/200 Msample, 4 channels
R&S
®
RTE1204
1326.2000.84
Hardware options (plug-in)
Mixed signal option, 400 MHz, 5 Gsample/s, 16 channels, 100 Msample/channel
R&S
®
RTE-B1
1326.3570.02
Digital extension port for R&S
®
RT-ZVCxx usage with R&S
®
RTE oscilloscope,
included in R&S
®
RTE-B1
R&S
®
RTE-B1E
1333.0750.02
Arbitrary waveform generator, 100 MHz, 2 analog channels, 8-bit pattern generator
R&S
®
RTE-B6
1326.3012.02
GPIB interface
R&S
®
RTE-B10
1317.4978.02
Replacement SSD hard disk, incl. firmware
R&S
®
RTE-B18
1317.7002.02
Bandwidth upgrade
11
Upgrade of R&S
®
RTE1022/1024 to 350 MHz bandwidth
R&S
®
RTE-B200
1326.1384.02
Upgrade of R&S
®
RTE1022/1024 to 500 MHz bandwidth
R&S
®
RTE-B201
1326.1390.02
Upgrade of R&S
®
RTE1022/1024 to 1 GHz bandwidth
R&S
®
RTE-B202
1326.1403.02
Upgrade of R&S
®
RTE1022/1024 to 1.5 GHz bandwidth
R&S
®
RTE-B203
1326.1410.02
Upgrade of R&S
®
RTE1022/1024 to 2 GHz bandwidth
R&S
®
RTE-B204
1326.1426.02
Upgrade of R&S
®
RTE1032/1034 to 500 MHz bandwidth
R&S
®
RTE-B205
1326.1432.02
Upgrade of R&S
®
RTE1032/1034 to 1 GHz bandwidth
R&S
®
RTE-B206
1326.1449.02
Upgrade of R&S
®
RTE1032/1034 to 1.5 GHz bandwidth
R&S
®
RTE-B207
1326.1455.02
Upgrade of R&S
®
RTE1032/1034 to 2 GHz bandwidth
R&S
®
RTE-B208
1326.1461.02
Upgrade of R&S
®
RTE1052/1054 to 1 GHz bandwidth
R&S
®
RTE-B209
1326.1478.02
Upgrade of R&S
®
RTE1052/1054 to 1.5 GHz bandwidth
R&S
®
RTE-B210
1326.1484.02
Upgrade of R&S
®
RTE1052/1054 to 2 GHz bandwidth
R&S
®
RTE-B211
1326.1490.02
Upgrade of R&S
®
RTE1102/1104 to 1.5 GHz bandwidth
R&S
®
RTE-B212
1326.1503.02
Upgrade of R&S
®
RTE1102/1104 to 2 GHz bandwidth
R&S
®
RTE-B213
1326.1510.02
Upgrade of R&S
®
RTE1152/1154 to 2 GHz bandwidth
R&S
®
RTE-B214
1326.1526.02
Software options
Serial triggering and decoding
I
2
C/SPI serial triggering and decoding
R&S
®
RTE-K1
1326.1178.02
UART/RS-232/RS-422/RS-485 serial triggering and decoding
R&S
®
RTE-K2
1326.1184.02
CAN/LIN serial triggering and decoding
R&S
®
RTE-K3
1326.1190.02
FlexRay™ serial triggering and decoding
R&S
®
RTE-K4
1326.1203.02
I²S serial triggering and decoding
R&S
®
RTE-K5
1326.1210.02
MIL-STD-1553 serial triggering and decoding
R&S
®
RTE-K6
1326.1226.02
ARINC 429 triggering and decoding
R&S
®
RTE-K7
1326.1232.02
Ethernet serial decoding
R&S
®
RTE-K8
1326.1332.02
CAN-FD serial triggering and decoding
R&S
®
RTE-K9
1326.1249.02
SENT serial triggering and decoding
R&S
®
RTE-K10
1326.1603.02
Manchester and NRZ serial triggering and decoding
R&S
®
RTE-K50
1326.1326.02
MDIO serial triggering and decoding
R&S
®
RTE-K55
1326.1255.02
IEEE 100BASE-T1 serial triggering and decoding
R&S
®
RTE-K57
1333.0609.02
USB 1.0/1.1/2.0/HSIC serial triggering and decoding
R&S
®
RTE-K60
1326.1610.02
USB power delivery serial triggering and decoding
R&S
®
RTE-K63
1326.3158.02
SpaceWire serial triggering and decoding
R&S
®
RTE-K65
1326.2845.02
CXPI serial triggering and decoding
R&S
®
RTE-K76
1326.3193.02
11
The bandwidth upgrade is performed at a Rohde & Schwarz service center, where the oscilloscope will also be calibrated.