Datasheet

Version 20.00, July 2019
Rohde & Schwarz R&S
®
RTE Oscilloscope 25
R&S
®
RTE-K3
CAN serial triggering and decoding
Protocol configuration
signal type
CAN_H, CAN_L
bit rate
100 bps to 1 Mbps
sampling point
5 % to 95 % within bit period
device list
associate frame identifier with symbolic ID,
load DBC file content
auto threshold setup
assisted threshold configuration for CAN
triggering and decoding
Trigger
source
any input channel or logical channel
trigger event setup
start of frame, frame type, identifier,
identifier + data, symbolic, error condition
(any combination of CRC error, bit stuffing
error, form error and ACK error)
identifier setup
frame type (data, remote or both),
identifier type (standard or extended);
condition =, ≠, ≥, ≤, in range, out of range
data setup
data pattern up to 8 byte (hex, decimal,
octal or binary); big-endian or little-endian;
condition =, ≠; ≥, ≤, in range, out of range
symbolic setup
message name, signal name; numeric
signal condition =, ≠, ≥, ≤, in range, out of
range; enumerated signal condition =, ≠,
≥, ≤
Decode
source
any input channel, math waveform,
reference waveform, logical channel
display type
decoded bus, logical signal, bus + logical
signal, tabulated list
color coding
start of frame, identifier, DLC, data
payload, CRC, end of frame, error frame,
overload frame, CRC error, bit stuffing
error
data format
hex, decimal, octal, binary, ASCII,
symbolic
Search
source
any input channel or logical channel
search event setup
combination of start of frame, frame type,
identifier, identifier + data, error condition
(any combination of CRC error, bit stuffing
error, form error and ACK error) or only
symbolic
event settings
same as trigger event settings