Datasheet
Version 20.00, July 2019
10 Rohde & Schwarz R&S
®
RTE Oscilloscope
Advanced trigger modes
Sequence trigger (A/B trigger)
triggers on B event after occurrence of A event; delay condition after A event specified
either as time interval or number of B events
A event
any trigger mode
B event
edge, glitch, width, runt, window, timeout,
interval, slew rate
Serial bus trigger
optional
see dedicated triggering and decoding
options
External trigger input
input impedance
50 Ω ± 1.5 % (meas.),
1 MΩ ± 1 % || 14 pF (meas.)
max. input voltage at 50 Ω
5 V (RMS)
max. input voltage at 1 MΩ
30 V (RMS)
derates at 20 dB/decade to 5 V (RMS)
above 5 MHz
trigger level range
±5 V
sensitivity, for input frequency ≤ 500 MHz
300 mV (V
pp
)
input coupling
AC, DC (50 Ω and 1 MΩ), GND,
HF reject (attenuates > 50 kHz),
LF reject (attenuates < 50 kHz)
trigger modes
edge (rise or fall)
Trigger out
functionality
a pulse is generated for every acquisition
trigger event
output voltage
0 V to 5 V at high impedance;
0 V to 2.5 V at 50 Ω
pulse width
selectable between 50 ns and 60 ms
pulse polarity
low active or high active
output delay
depends on trigger settings
jitter
±600 ps (meas.)