User Manual
Remote Commands Reference
R&S
®
RTC1000
290User Manual 1335.7352.02 ─ 04
Return values: 
<Acknowledge> INComplete | ACK | NACK | EITHer
INComplete
Acknowledge is incomplete
ACK
Acknowledge
NACK
No Acknowledge
EITHer
ACK or NACK
Usage:  Query only
BUS<b>:I2C:FRAMe<n>:BYTE<o>:COMPlete?
Returns the information whethera data byte of a frame is received complete.
Suffix: 
<b>
.
1, 2
Selects the bus.
<n> Selects the frame.
<o> Selects the byte number.
Return values: 
<ByteComplete> ON | OFF
ON
Data byte was received completely.
OFF
Data byte was not received completely.
Usage:  Query only
13.16.6  UART
● UART - Configuration............................................................................................290
● Trigger...................................................................................................................292
● Decode..................................................................................................................294
13.16.6.1  UART - Configuration
BUS<b>:UART:DATA:SOURce........................................................................................ 291
BUS<b>:UART:DATA:POLarity........................................................................................ 291
BUS<b>:UART:SSIZe.....................................................................................................291
BUS<b>:UART:PARity.................................................................................................... 291
BUS<b>:UART:SBIT.......................................................................................................292
BUS<b>:UART:BAUDrate............................................................................................... 292
BUS<b>:UART:BITime....................................................................................................292
Protocol Analysis