Waveform measurements
Automatic measurements
measurements on channels,
math waveforms, reference waveforms
burst width, count positive pulses, count
negative pulses, count falling edges,
count rising edges, mean value, RMS,
peak-to-peak, peak+, peak-, frequency,
period, amplitude, crest factor, top level,
base level, pos overshoot, neg overshoot,
pulse width+, pulse witdh-, duty cycle+,
duty cycle-, rise time (80 %, 90 %),
fall time (80 %, 90 %), delay, phase,
standard deviation
measurements on trigger signal
trigger period, trigger frequency
implemented by means of six-digit
hardware counter
number of active measurements
6
Cursor measurements
measurements on channels,
math waveforms, reference waveforms
voltage (V1, V2, ΔV), time (t1, t2, Δt,
1/Δt), ratio X, ratio Y, pulse and edge
count (pos./neg.), peak values (V
pp
, V
p
+,
V
pp
-), V
mean
, V
RMS
, standard deviation, duty
cycle (pos./neg.), rise/fall time (80 %,
90 %), crest factor, voltage at the cursor
position
functions
x and y tracking, coupling of cursors, set
to screen, set to trace, automatic source
Quick measurements
function
fast overview of measurements from one
channel,
some measurements displayed with result
lines in diagram
sources
channel 1, channel 2
measurements displayed in diagram
mean value, max. peak, min. peak, rise
time, fall time
numerically displayed measurements
RMS, peak-to-peak voltage, period,
frequency, plus 6 automatic
measurements selectable
Marker
up to 8 freely positionable markers for
easy navigation
Digital voltmeter
Accuracy
related to channel settings of voltmeter
source
Measurements
DC, AC+DC
RMS
, AC
RMS
Sources
channel 1, channel 2
Number of measurements
up to 4
Resolution
up to 3 digits
Frequency counter
Measurements
frequency, period
Sources
trigger signal source (edge, video): line,
channel 1, channel 2, external trigger in
Number of measurements
2
Resolution
5 digits
Frequency range
0. 03 Hz to bandwidth of scope (limited by
bandwidth of trigger filter)
Component tester
Parameters
voltage (X), current (Y)
Selectable frequencies
50 Hz, 200 Hz
Component tester output
(Aux Out connector)
max. output voltage (open circuit)
10 V (V
p
)
± 5 %
max. output current (short circuit)
10 mA ± 10 %
reference potential
ground