Datasheet
Rohde & Schwarz R&S®RTB2000 Digital Oscilloscope 9
History and segmented memory mode
The R&S®RTB-K15 history function option increases the memory
from 10Msample to 160Msample. Users scroll through past ac-
quisitions and analyze the data using all of the oscilloscope tools,
e.g. protocol decode and logic channels. In ultra-segmented mode,
waveforms are seamlessly captured before visualization. Serial
protocol and pulse sequences are recorded practically without
interruptions.
Mask test mode
Mask tests quickly reveal whether a specific signal lies within de-
fined tolerance limits. By using statistical pass/fail evaluation, they
assess quality and stability of a DUT. Signal anomalies and unex-
pected results are quickly identified. When the mask is violated,
the measurement stops. Each violation can generate a pulse out-
put at the AUX-OUT connector on the R&S®RTB2000. This pulse
output can be used to trigger actions in the measurement setup.
Digital voltmeter
The R&S®RTB2000 features a three-digit voltmeter (DVM) and six-
digit frequency counter on each channel for simultaneous mea-
surements. Measurement functions include DC, AC+DC
RMS
and
AC
RMS
– included in scope of delivery.
Frequency analysis mode
Difficult-to-find faults often result from the interaction between
time and frequency signals. The FFT function of the R&S®RTB2000
is activated with the push on a button and by just entering center
frequency and span. Due to the high-performance FFT function-
ality of the R&S®RTB2000 oscilloscopes, signals can be analyzed
with up to 128 kpoints. Other practical tools include cursor mea-
surements, detection of signal peaks and autoset in frequency
domain.
RTB2000_bro_en_3607-4270-12_v0202.indd 9 16.02.2017 11:57:17