Datasheet

Version 03.00, January 2017
8 Rohde & Schwarz R&S
®
RTB Digital Oscilloscope
Mask testing
Sources
R&S
®
RTB2002
channel 1, channel 2
R&S
®
RTB2004
channel 1, channel 2, channel 3,
channel 4
Mask definition
acquired waveform with user-defined
tolerance, can be stored and restored
Result statistics
completed acquisitions, passed and failed
acquisitions (absolute and in percent),
test duration
Actions on mask violation
sound, acquisition stop, screenshot, save
waveform, pulse out (AUX OUT
connector)
Waveform maths
Number of math waveforms
1
Functions
addition, subtraction, multiplication,
division
Sources
R&S
®
RTB2002
channel 1, channel 2
R&S
®
RTB2004
channel 1, channel 2, channel 3,
channel 4
FFT
sources
R&S
®
RTB2002
channel 1, channel 2
R&S
®
RTB2004
channel 1, channel 2, channel 3,
channel 4
setup parameters
start frequency, stop frequency, center
frequency, frequency span,
vertical scale, vertical position
windows
Hanning, Hamming, Blackman,
rectangular, flat top
waveform arithmetic
none, envelope, average (selectable 2 to
100 000)
Search function
Functions
search types
edge, width, peak, rise/fall time, runt,
data2clock, pattern, protocol (available
with R&S
®
RTB-K3 option)
configuration
manual level setting, adjustable hysteresis
display of search events
in diagram (markers) and in result table
Sources
R&S
®
RTB2002
channel 1, channel 2,
math waveform, D0 to D15 (with
R&S
®
RTB-B1 option)
R&S
®
RTB2004
channel 1, channel 2, channel 3,
channel 4, math waveform, D0 to D15
(with R&S
®