Datasheet
Version 03.00, January 2017
Rohde & Schwarz R&S
®
RTB2000 Digital Oscilloscope 5
Acquisition system
Maximum realtime sampling rate
normal mode
1.25 Gsample/s
interleaved mode,
following channels are not used
simultaneously:
channel 1 and channel 2
channel 3 and channel 4
logic channels
2.5 Gsample/s
Memory depth per channel
normal
10 Msample per channel
If following channels are not used
simultaneously:
channel 1 and channel 2
channel 3 and channel 4
logic channels
20 Msample per channel
Acquisition modes
sample
first sample in decimation interval
peak detect
largest and smallest sample in decimation
interval
high resolution
average value of all samples in decimation
interval
envelope
envelope of acquired waveforms
average
average over a series of acquired
waveforms
envelope + peak detect
envelope of acquired waveforms with
active peak detect
Number of averaged waveforms
2 to 100 000
Waveform acquisition rate
dot display, single channel, auto record
length
up to 50 000 waveforms/s
Trigger system
Trigger level
range (min)
±5 div from center of screen
Trigger modes
auto, normal, single,
n single with R&S
®
RTB-K15 option
Hold-off range
time
inactive or 50 ns to 10 s
Trigger types
edge, width, video, pattern, serial bus,
timeout, line
Edge trigger
trigger events
rising edge, falling edge, both edges
sources
R&S
®
RTB2002
channel 1, channel 2, logic channels from
D0 to D15 (with R&S
®
RTB-B1 option),
external trigger input
R&S
®
RTB2004
channel 1, channel 2, channel 3,
channel 4, logic channels from D0 to D15
(with R&S
®
RTB-B1 option), external
trigger input
coupling (analog channels, external trigger
input)
DC, AC,
HF reject (attenuates > 50 kHz (meas.)),
LF reject (attenuates < 50 kHz (meas.)),
noise reject (enlarges trigger hysteresis)
Width trigger
trigger events
pulse width is smaller, greater, equal,
unequal, inside interval, outside interval
min. pulse width
6.4 ns
max. pulse width
13.5 s
polarity
positive, negative
sources
R&S
®
RTB2002
channel 1, channel 2, logic channels from
D0 to D15 (with R&S
®
RTB-B1 option)
R&S
®
RTB2004
channel 1, channel 2, channel 3,
channel 4, logic channels from D0 to D15
(with R&S
®