Rohde & Schwarz R&S®NGM200 Power Supply Series 17
R&S®NGM201, front view R&S®NGM202, front view R&S®NGM202, rear view
General data
Environmental conditions
Temperature operating temperature range +5 °C to +40 °C
storage temperature range –20 °C to +70 °C
Humidity noncondensing 5 % to 95 %
Power rating
Mains nominal voltage 100 V/115 V/230 V (± 10 %)
Mains frequency 50 Hz to 60 Hz
Maximum power consumption 400 W
Mains fuses 2 × T4.0H/250 V
Product conformity
Electromagnetic compatibility EU: in line with
Radio Equipment Directive 2014/53/EU
applied standards:
ETSI EN 300328 V2.1.1
EN 61326-1
EN 55011 (Class A)
EN 55032 (Class A)
ETSI EN 301489-1 V2.2.0
ETSI EN 301489-17 V3.2.0
Korea KC mark
Electrical safety EU:
in line with Low Voltage Directive 2014/35/EU
applied harmonized standards:
EN 61010-1
USA, Canada CSA-C22.2 No. 61010-1
WLAN approvals Austria, Belgium, Bulgaria, Croatia, Cyprus,
Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Liechtenstein, Lithuania,
Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Romania, Slovakia, Slovenia,
Spain, Sweden, Switzerland, Turkey, United
Kingdom
CE0682
Singapore iMDA standards DB102020
USA, Canada FCC, IC
RoHS in line with EU Directive 2011/65/EU EN 50581
Mechanical resistance
Vibration sinusoidal 5 Hz to 55 Hz, 0.3 mm (peak-to-peak)
55 Hz to 150 Hz, 0.5 g const.,
in line with EN 60068-2-6
wideband noise 8 Hz to 500 Hz, acceleration: 1.2 g (RMS),
in line with EN 60068-2-64
Shock 40 g shock spectrum,
in line with MIL-STD-810E, method 516.4,
procedure I
Mechanical data
Dimensions W × H × D 222 mm × 97 mm × 436 mm
(8.74 in × 3.82 in × 17.17 in)
Weight R&S®NGM201 7.2 kg (15.9 lb)
R&S®NGM202 7.4 kg (16.3 lb)
Rack installation R&S®HZN96 option
Recommended calibration interval operation 40 h/week over entire range of
specified environmental conditions
1 year