R&S®FPC1000 Spectrum Analyzer Specifications Data Sheet | Version 01.00 year FPC1000_dat-sw_5214-7122-22_v0100.indd 1 15.12.
Version 01.00, December 2016 CONTENTS Definitions ....................................................................................................................................................................... 3 Specifications .................................................................................................................................................................. 4 Frequency .....................................................................................................
Version 01.00, December 2016 Definitions General Product data applies under the following conditions: Three hours storage at ambient temperature followed by 30 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter.
Version 01.00, December 2016 Specifications Specifications apply under the following conditions: 15 minutes warm-up time at ambient temperature, specified environmental conditions met, calibration cycle adhered to. Data without tolerances: typical values only. Data designated as “nominal” applies to design parameters and is not tested. Data without tolerance limits is not binding.
Version 01.00, December 2016 Level Display range Maximum rated input level DC voltage CW RF power Peak RF power Max. pulse voltage Max. pulse energy Intermodulation Third-order intercept (TOI), Second harmonic intercept (SHI) displayed noise floor to +30 dBm 50 V 33 dBm (= 2 W) 36 dBm (= 4 W) 150 V 10 mWs duration < 3 s pulse width 10 µs intermodulation-free dynamic range, signal level 2 × –20 dBm, RF attenuation = 0 dB, RF preamplifier = off fin = 1 GHz +7 dBm (meas.) fin = 2.4 GHz +10 dBm (meas.
Version 01.00, December 2016 Trigger functions Trigger Trigger source External trigger level threshold low → high transition high → low transition maximum free run, video, external 2.4 V 0.7 V 3.0 V 5 kHz ≤ f ≤ 1 GHz 1 GHz < f ≤ 3 GHz RF input only 50 Ω (nom.) N female < 1.5 (nom.) < 2 (nom.
Version 01.00, December 2016 General data Power supply AC supply input specifications 100 V AC to 240 V AC, 50 Hz to 60 Hz, 0.6 A to 0.4 A 14 W (nom.) IEC 61010-1, EN 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010.
Version 01.00, December 2016 Ordering information Designation Spectrum Analyzer, 9 kHz to 1 GHz Accessories supplied Power cable, USB cable for connection to PC Type R&S®FPC1000 Order No. 1328.6660.02 Type R&S®FPC-B2 R&S®FPC-B3 R&S®FPC-B22 R&S®FPC-K7 R&S®FPC-K43 R&S®FPC-K53 R&S®FPC-K55 R&S®FPC-B200 Order No. 1328.6677.02 1328.6683.02 1328.6690.02 1328.6748.02 1328.6754.02 1328.6977.02 1328.6760.02 1328.6990.02 Type Order No. 1328.7080.02 1305.0289.02 1333.1734.
Version 01.
Version 01.
Version 01.
Service that adds value Worldwide Local and personalized ❙ Customized and flexible ❙ Uncompromising quality ❙ Long-term dependability ❙ ❙ About Rohde & Schwarz The Rohde & Schwarz electronics group offers innovative solutions in the following business fields: test and measurement, broadcast and media, secure communications, cybersecurity, radiomonitoring and radiolocation.