User Manual
Remote Control
R&S
®
FPC
292User Manual 1178.4130.02 ─ 05
●
Impedance:
INPut:IMPedance
INPut:IMPedance:PAD
DISPlay<n>[:WINDow]:TRACe<t>:Y[:SCALe]:PDIVision.................................................... 292
DISPlay<n>[:WINDow]:TRACe<t>:Y[:SCALe]:PDIVision <Scale>
This command defines the range of the y-axis for the graphical results.
Suffix:
<n>
.
irrelevant
<t> irrelevant
Parameters:
<Scale> <numeric value> (integer only)
The unit depends on the result.
• PCT for AM results (0.1 to 100 % per grid division).
• Hz for FM results (1 kHz to 1 MHz per grid division).
Example: //Define grid scale of AM results (50 percent per grid)
CALC:FEED 'XTIM:AM'
DISP:TRAC:Y:PDIV 50
17.14.4 Bandwidth
[SENSe:]ADEMod:BWIDth:DEModulation.........................................................................292
[SENSe:]ADEMod:BANDwidth:DEModulation................................................................... 292
[SENSe:]FILTer:DEMPhasis[:STATe]................................................................................ 292
[SENSe:]FILTer:DEMPhasis:TCONstant........................................................................... 293
[SENSe:]FILTer:LPASs................................................................................................... 293
[SENSe:]ADEMod:BWIDth:DEModulation <Bandwidth>
[SENSe:]ADEMod:BANDwidth:DEModulation <Bandwidth>
This command selects the demodulation bandwidth.
Parameters:
<Bandwidth> <numeric value> (integer only)
Refer to the datasheet for a list of supported bandwidths.
*RST: 200 kHz
Default unit: Hz
Example: //Select demodulation bandwidth
ADEM:BAND:DEM 50KHZ
[SENSe:]FILTer:DEMPhasis[:STATe] <State>
This command turns the deemphasis filter on and off.