Return values:
<Data> <numeric value>
The R&S FPC returns 1183 values. Each value corresponds to
one pixel of a trace.
The unit depends on the measurement and the unit you have
set with UNIT<n>:POWer
Note: If you use the auto peak detector, the command reads out
positive peak values only.
Example: //Read out the data for trace 1.
TRAC:DATA? TRACE1
Usage: Query only
17.12.8
Marker
CALCulate<n>:DELTamarker<m>:AOFF...........................................................................258
CALCulate<n>:DELTamarker<m>:MAXimum:NEXT...........................................................259
CALCulate<n>:DELTamarker<m>:MAXimum[:PEAK].........................................................259
CALCulate<n>:DELTamarker<m>:MINimum[:PEAK].......................................................... 259
CALCulate<n>:DELTamarker<m>[:STATe]........................................................................ 259
CALCulate<n>:DELTamarker<m>:X................................................................................. 260
CALCulate<n>:DELTamarker<m>:X:RELative................................................................... 260
CALCulate<n>:DELTamarker<m>:Y?............................................................................... 261
CALCulate<n>:MARKer<m>:AOFF..................................................................................262
CALCulate<n>:MARKer<m>:FREQuency:MODE.............................................................. 262
CALCulate<n>:MARKer<m>:FUNCtion:CENTer................................................................ 262
CALCulate<n>:MARKer<m>:FUNCtion:REFerence........................................................... 262
CALCulate<n>:MARKer<m>:MAXimum:NEXT.................................................................. 263
CALCulate<n>:MARKer<m>:MAXimum[:PEAK]................................................................ 263
CALCulate<n>:MARKer<m>:MINimum[:PEAK]................................................................. 263
CALCulate<n>:MARKer<m>[:STATe]............................................................................... 264
CALCulate<n>:MARKer<m>:X........................................................................................ 264
CALCulate<n>:MARKer<m>:X:SLIMits<slim>:LEFT.......................................................... 264
CALCulate<n>:MARKer<m>:X:SLIMits<slim>:RIGHt......................................................... 265
CALCulate<n>:MARKer<m>:X:SLIMits<slim>[:STATe]....................................................... 266
CALCulate<n>:MARKer<m>:Y?.......................................................................................266
CALCulate<n>:DELTamarker<m>:AOFF
This command turns off all active delta markers.
Suffix:
<n>
.
irrelevant
<m> irrelevant
Example: //Turn off all delta markers
CALC:DELT:AOFF
Usage: Event