User Manual
Remote Control
R&S
®
FPC
248User Manual 1178.4130.02 ─ 05
Effects of this command
●
Turns off automatic selection of resolution bandwidth ([SENSe:]BANDwidth[:
RESolution]:AUTO).
Parameters:
<Bandwidth> <numeric value> (integer)
Value adjustable in 1 - 3 steps (1 Hz, 3 Hz, 10 Hz, etc.).
In addition, you can select a 200 kHz bandwidth.
Range: 1 Hz to 3 MHz
*RST: - (AUTO is set to ON)
Default unit: Hz
Example: //Define resolution bandwidth
BAND 100KHZ
[SENSe:]BWIDth[:RESolution]:AUTO
<Bandwidth>
[SENSe:]BANDwidth[:RESolution]:AUTO <State>
This command turns automatic selection of the resolution bandwidth (or measurement
bandwidth) on and off.
Effects of this command
●
Turn on automatic RBW selection to couple the RBW to the span.
When you turn off automatic selection of the resolution bandwidth, you can select one
manually with [SENSe:]BANDwidth[:RESolution].
Parameters:
<State> ON | OFF | 1 | 0
*RST: ON | 1
Example: //Turn on automatic RBW selection
BAND:AUTO OFF
[SENSe:]BWIDth:VIDeo <Bandwidth>
[SENSe:]BANDwidth:VIDeo <Bandwidth>
This command selects the video bandwidth.
Effects of this command
●
Turns off automatic selection of video bandwidth ([SENSe:]BANDwidth:VIDeo:
AUTO).
Parameters:
<Bandwidth> <numeric value> (integer)
Value adjustable in 1 - 3 steps (1 Hz, 3 Hz, 10 Hz, etc.).
Range: 1 Hz to 3 MHz
*RST: - (AUTO is set to ON)
Default unit: Hz
Remote Commands of the Spectrum Application