User Manual
Remote Control
R&S
®
FPC
247User Manual 1178.4130.02 ─ 05
Prerequisites for this command
●
Select a transducer ([SENSe:]CORRection:TRANsducer<td>:SELect).
Suffix:
<td>
.
Transducer
Parameters:
<State> ON | OFF | 1 | 0
*RST: OFF | 0
Example: //Turn on primary transducer
CORR:TRAN1:SEL 'HE200A-20-200.pritrd'
CORR:TRAN1 ON
//Turn on secondary transducer
CORR:TRAN2:SEL 'PreAmp.sectrd'
CORR:TRAN2 ON
UNIT<n>:POWer
<Unit>
This command selects the unit displayed on the y-axis.
Suffix:
<n>
.
irrelevant
Parameters:
<Unit> DBM | DBUV | DBMV | V | W | DUVM | DUAM | V_M | W_M2
Note that the availability of units depends on the operating
mode.
*RST: dBm
Example: //Select displayed unit
UNIT:POW DBUV
17.12.4 Bandwidth
[SENSe:]BWIDth[:RESolution].........................................................................................247
[SENSe:]BANDwidth[:RESolution]................................................................................... 247
[SENSe:]BWIDth[:RESolution]:AUTO...............................................................................248
[SENSe:]BANDwidth[:RESolution]:AUTO..........................................................................248
[SENSe:]BWIDth:VIDeo..................................................................................................248
[SENSe:]BANDwidth:VIDeo............................................................................................ 248
[SENSe:]BWIDth:VIDeo:AUTO........................................................................................249
[SENSe:]BANDwidth:VIDeo:AUTO...................................................................................249
[SENSe:]BWIDth[:RESolution] <Bandwidth>
[SENSe:]BANDwidth[:RESolution] <Bandwidth>
This command selects the resolution bandwidth (or measurement bandwidth).
Remote Commands of the Spectrum Application