User Manual
Remote Control
R&S
®
FPC
232User Manual 1178.4130.02 ─ 05
Example: //Define the burst length
CALC:MARK:FUNC:TDMA:BURS 80 US
17.12.1.6 Harmonic Distortion
The following remote commands are exclusive to the harmonic distortion measure-
ment.
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:DISTortion?........................................ 232
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:LIST?.................................................232
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:NHARmonics......................................233
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:PRESet..............................................233
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics[:STATe].............................................. 234
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:DISTortion? <ResultType>
This command queries the total harmonic distortion of the signal.
To get a valid result, you have to perform a complete sweep with synchronization to the
sweep end between activating the delta marker and reading out the result. This is only
possible in single sweep mode.
Prerequisites for this command
●
Turn on the harmonic distortion measurement (CALCulate<n>:MARKer<m>:
FUNCtion:HARMonics[:STATe] on page 234).
Suffix:
<n>, <m>
.
irrelevant
Query parameters:
<ResultType> TOTal
Return values:
<THD> Pair of values, one showing the THD in %, one in dB.
Example: See CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:
PRESet
Usage: Query only
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:LIST?
This command queries the position of the harmonics.
To get a valid result, you have to perform a complete sweep with synchronization to the
sweep end between activating the delta marker and reading out the result. This is only
possible in single sweep mode.
Prerequisites for this command
●
Turn on the harmonic distortion measurement (CALCulate<n>:MARKer<m>:
FUNCtion:HARMonics[:STATe] on page 234).
Suffix:
<n>, <m>
.
irrelevant
Remote Commands of the Spectrum Application