User Manual

Remote Control
R&S
®
FPC
232User Manual 1178.4130.02 ─ 05
Example: //Define the burst length
CALC:MARK:FUNC:TDMA:BURS 80 US
17.12.1.6 Harmonic Distortion
The following remote commands are exclusive to the harmonic distortion measure-
ment.
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:DISTortion?........................................ 232
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:LIST?.................................................232
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:NHARmonics......................................233
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:PRESet..............................................233
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics[:STATe].............................................. 234
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:DISTortion? <ResultType>
This command queries the total harmonic distortion of the signal.
To get a valid result, you have to perform a complete sweep with synchronization to the
sweep end between activating the delta marker and reading out the result. This is only
possible in single sweep mode.
Prerequisites for this command
Turn on the harmonic distortion measurement (CALCulate<n>:MARKer<m>:
FUNCtion:HARMonics[:STATe] on page 234).
Suffix:
<n>, <m>
.
irrelevant
Query parameters:
<ResultType> TOTal
Return values:
<THD> Pair of values, one showing the THD in %, one in dB.
Example: See CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:
PRESet
Usage: Query only
CALCulate<n>:MARKer<m>:FUNCtion:HARMonics:LIST?
This command queries the position of the harmonics.
To get a valid result, you have to perform a complete sweep with synchronization to the
sweep end between activating the delta marker and reading out the result. This is only
possible in single sweep mode.
Prerequisites for this command
Turn on the harmonic distortion measurement (CALCulate<n>:MARKer<m>:
FUNCtion:HARMonics[:STATe] on page 234).
Suffix:
<n>, <m>
.
irrelevant
Remote Commands of the Spectrum Application