Datasheet
Version 05.00, February 2019
12 Rohde & Schwarz R&S
®
FPC Spectrum Analyzer
0,0
5,0
10,0
15,0
20,0
25,0
30,0
0,00
0,50
1,00
1,50
2,00
2,50
3,00
3,50
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
Phase uncertainty in
°
Magnitude uncertainty in dB
Return loss in dB
Magnitude: 2 MHz < f < 3 GHz
Phase: 2 MHz < f < 3 GHz
Distance-to-fault analysis
Result formats
return loss, VSWR with average and
maximum indication
Return loss
Range
1/2/5/10/20/50/100/120/150 dB,
linear 100 %
Resolution
0.1 dB
VSWR
Range
selectable
1 to 1.5, 2, 6, 11, 21 or 71
Fault resolution in meters
(1.5 × 10
8
× velocity factor/span)
Maximum cable length
depending on cable loss
1500 m (nom.)
Immunity to interference
Maximum permissible spurious signal
measurement = reflection (S
11
)/1 – port cable loss/distance-to-fault analysis
+17 dBm (nom.)
Uncertainty of reflection measurements with the R&S
®
ZN-Z103 calibration unit;
temperature: +18 °C to +25 °C, RBW: 10 Hz, power: –10 dBm.