Datasheet

Version 05.00, February 2019
Rohde & Schwarz R&S
®
FPC Spectrum Analyzer 11
Transmission measurement S
21
Result formats
magnitude
Magnitude
Range
1/2/5/10/20/50/100/120/150 dB,
linear 100 %
Resolution
0.1 dB
Dynamic range
80 dB (nom.)
Reflection measurement S
11
Result formats
magnitude, VSWR, distance-to-fault,
Smith chart, phase
Magnitude
Range
1/2/5/10/20/50/100/120/150 dB,
linear 100 %
Resolution
0.1 dB
VSWR
Range
selectable
1 to 1.5, 2, 6, 11, 21 or 71
Measurement speed
0.3 ms per point
Corrected directivity with R&S
®
ZN-Z103
2 MHz ≤ f ≤ 3 GHz
> 42 dB (nom.)
Corrected test port match
with R&S
®
ZN-Z103
2 MHz ≤ f ≤ 3 GHz
> 36 dB (nom.)
Measurement uncertainty
with R&S
®
ZN-Z103
see figure Uncertainty of reflection
measurement
1-port cable loss measurement
Result format
magnitude
Range
selectable
1/2/5/10/20/50/100/120/150 dB
Resolution
0.1 dB