User manual
53
Subject to change without notice
O p t i o n a l A c c e s s o r i e s l
12 Optional Accessories
12.1 Activation of the PreamplierHO3011
The PreamplierfortheseriesHMS(DANL–135dBmtyp./100
RBW) will activate in the Setup menu with the softkey UPGRADE.
Please look at chapter 8.7 for the procedure of the upgrade. This
preamplierisn‘tincludedinthesuppliedaccessoriesandcan
be acquired by purchase.
12.2 19‘‘ Rack mount kit 4HE HZ46
For the application in rack systems HAMEG provides a kit for
the HMS series. Technical details and a description about the
mountingyoucanndinthemanualHZ46onourhomepage
http://www.hameg.com/downloads.
12.3 Carrying case HZ99
The Carrying Case HZ99 is used to transport your spectrum
analyzer and is available ‚on stock‘.
Fig. 12.1: Carrying case HZ99
12.4 NeareldprobeHZ530/HZ540
The set includes 3 hand-held probes with a built-in preampli-
ercoveringthefrequency range from 100 kHz to 1 GHz resp.
!1 MHz to 3 GHz. When used in conjuction with a spectrum ana-
lyzer or a measuring receiver, the probes can be used to locate
and qualify EMI sources, as well as evaluate EMC problems at
the breadboard and prototype level. The power can be supplied
either from batteries (HZ530) or through a power cord directly
connected to an spectrum analyzer (HZ540). Signal feed is via
a BNC-cable or SMA/N-cable. They enable the user to evaluate
radiatedeldsandperformshieldeffectivenesscomparisons.
Theprobes–onemagneticeldprobe,oneelectriceldprobe
andonehighimpedanceprobe–areallmatchedtothe50Ω
inputsofspectrumanalyzers.Thetechnicalspecicationsare
described in the HZ530/HZ540 manual on our homepage http://
www.hameg.com/downloads.
12.5 Measurements of spectra with a VSWR bridge
HZ547 (HMS1010/3010)
Fig. 12.2: VSWR bridge HZ547 for HMS1010/3010
The VSWR bridge HZ57 allows the measurement of the voltage
standingwaveratio(VSWR)andthereflectioncoefcientof50Ω
devices.Typicalobjectsaree.g.50Ωattenuators,loadresistors,
ampliers, cables, mixers,frequency selective devices. The
frequencyrangeis100kHz...3GHz.Thetechnicalspecications
and the measurement set-up are decribed in the HZ547 manual
on our homepage http://www.hameg.com/downloads.
12.6 Transient Limiter HZ560
The Transient Limiter HZ560 protects the input circuit of
spectrum analyzers and measurement receivers, in particular
in combination with the use of a Line Impedance Stabilization
Network(i.e.LISNHM6050).Thetechnicalspecicationsare
decribed in the HZ560 manual on our homepage http://www.
hameg.com/downloads.
12.7 75/50-Ω-ConverterHZ575
TheconverterHZ575hasa75ΩACcoupledinputanda50ΩDC
coupledoutput.UsingHZ575,spectrumanalyzerswith50Ωinput
canbeusedformeasurementin75Ωenvironment.HZ575can
beusedreversedtoo.A50Ωsignalappliedatthe50Ω“output“
ispresentatthe75ΩBNC“input“socketwithanimpedance
of75Ω.ThetechnicalspecicationsaredecribedintheHZ575
manual on our homepage http://www.hameg.com/downloads.