1 Installation and safety instructions
1.1 Setting up the instrument
Ascanbeseenfromthegures,thehandlecanbesetinto
different positions:
A and B = carrying
C = horizontal operating
D and E = operating at different angles
F = handle removal
G = operating using the feet‘s, batch use and for shipping in
original packaging
Attention!
When changing the handle position, the instrument
must be placed so that it cannot fall (e.g. placed on
a table). Then the handle locking knobs must be
simultaneously pulled outwards and rotated to the
required position. Without pulling the locking knobs
they will latch in into the next locking position.
Removal/ttingofthehandle: The handle can be removed in
position F, pulling the side parts outside the housing. Adding
the handle works vice versa.
1.2 Safety
The instrument ful ls the VDE 0411 part1 regulations for
electrical measuring, control and laboratory instruments and
was manufactured and tested accordingly. It left the factory in
perfect safe condition. Hence it also corresponds to European
Standard EN 61010-1 and International Standard IEC 1010-1.
In order to maintain this condition and to ensure safe opera-
tion the user is required to observe the warnings and other
directions for use in this manual. Housing, chassis as well as
all measuring terminals are connected to safety ground of the
mains. All accessible metal parts were tested against the mains
with 2200 V
DC
. The instrument conforms to safety class I. The
oscilloscope may only be operated from mains outlets with a
safety ground connector. The mains plug has to be installed
prior to connecting any signals. It is prohibited to separate the
safety ground connection. If suspected that safe operation may
not be guaranteed do not use the instrument any more and lock
it away in a secure place.
Safe operation may be endangered if any of the following was
noticed:
in case of visible damage.
in case loose parts were noticed
if it does not function any more.
after prolonged storage under unfavourable conditions (e.g.
like in the open or in moist atmosphere).
– after any improper transport (e.g. insuf cient packing
not conforming to the minimum standards of post, rail or
transportrm)
1.3 Correct operation
Please note: This instrument is only destined for use by perso-
nnel well instructed and familiar with the dangers of electrical
measurements. For safety reasons the oscilloscope may only
be operated from mains outlets with safety ground connector.
It is prohibited to separate the safety ground connection. The
plug must be inserted prior to connecting any signals. The
oscilloscope is destined for operation in industrial, business,
manufacturing, and domestic sites.
1.4 Ambient conditions
Operating ambient temperature: +5 °C to +40 °C. During trans-
port or storage the temperature may be –20 °C to +70°C. Please
note that after exposure to such temperatures or in case of
condensation, proper time must be allowed until the instrument
has reached the permissible temperature, and until the con-
densation has evaporated before it may be turned on! Ordinarily
this will be the case after 2 hours. The oscilloscope is destined
for use in clean and dry environments. Do not operate in dusty
or chemically aggressive atmosphere or if there is danger of
explosion. The any operating position may be used, however,
sufcient ventilation must beensured. Prolongedoperation
requires the horizontal or inclined position.
Do not obstruct the ventilation holes!
Specicationsarevalidaftera30minutewarm-upperiodat23
degr.C(tolerance±2degr.C).Specicationswithouttolerances
are average values.