Datasheet
Technical Data
Neareld Probe Set
HZ540(L) / HZ550(L)
Valid at 23 °C after a 30 minutes warm-up period
HZ551 Electric Field Probe
Frequency range: 1 MHz to approx. 3 GHz
Directional sensitivity: Omnidirectional, Sensitive to
electrical fields
Output impedance: 50 Ω; SMA-connector
Power supply: 6 V / 80 mA
HZ552 Magnetic Field Probe
Frequency range: <30 MHz to approx. 3 GHz
Directional sensitivity: like frame antenna, Sensitive to
changing magnetic fields
Output impedance: 50 Ω; SMA-connector
Power supply: 6 V / 80mA
HZ553 High Impedance Probe
Frequency range: <1 MHz bis ca. 3 GHz
Input impedance: <2 pF II 250 kΩ
Attenuation: in the range of
approx. 10:1 up to 30 : 1
Max. input voltage: 10 Vpp
Max. voltage of a non-insulated
conductor:
30 V
Output impedance: 50 Ω; SMA-connector
Power supply: 6 V / 80 mA
HZ554 Magnetic Field Probe (small sensor)
Frequency range: <50 MHz to approx. 3 GHz
Directional sensitivity: like frame antenna, Sensitive to
changing magnetic fields, High
spatial resolution due to very small
sensor area
Max. voltage of a non-insulated
conductor:
30 V
Output impedance: 50 Ω; SMA-connector
Power supply: 6 V / 80 mA
HZ555 Niedrig-Kapazitive-Sonde
Frequency range: 0.25 MHz to approx. 3 GHz
Input impedance: <0,2 pF II 250 kΩ
Attenuation: 10 : 1
Max. input voltage: 5 Vpp
Max. voltage of a non-insulated
conductor:
30 V
Output impedance: 50 Ω; SMA-connector
Power supply: 6 V / 80 mA
HZ556 Radiation Probe
Frequency range:
<
30 MHz to approx. 3 GHz
Directional sensitivity: like frame antenna. Sensitive to
changing magnetic fields, Radiation
of changing magnetic fields
Max. input power: 0.5 W (short term)
Output impedance: 50 Ω; SMA-connector
Divers
Dimensions (H x W x L):: 13 x 27 x 70 mm (+ antenna at
HZ551)
Power supply from HAMEG Series 5000 Spectrum analyzers
Package content:
Probe Probe-Set
HZ540
Probe-Set
HZ540 L
Probe-Set
HZ550
Probe-Set
HZ550 L
HZ551 • • • •
HZ552 • • • •
HZ553 • •
HZ554 • •
HZ555 • •
HZ556 • •
Accessories included:
HZ540 1 HZ551 Electrical Field Probe
1 HZ552 Magnetic Field Probe
1 HZ553 High Impedance Probe
1 SMA to N-Cable 1.2 m
Case
User manual
HZ550 1 HZ540 Basic Set
1 HZ554 Magnetic Field Probe
1 HZ556 Active antenna
1 SMA to N-Cable 1.2 m
Probe Set HZ540L und HZ550L
LHZ540L = HZ540 (without HZ553) + HZ555 Low Capacitance Probe
HZ550L = HZ550 (without HZ553) + HZ555 Low Capacitance Probe