Datasheet
2
Accessories supplied:
Line cord, Operating manual
Line Impedance Stabilization Network
HM6050-2
All data valid at 23 °C after 30 minutes warm-up.
Frequency Range: 10 kHz to 30 MHz
Impedance Characteristics: Z =50Ω||(50µH+5Ω),
Error <20 % under terms of VDE 876T1
Max. Current: 16 A
Line Voltage/Frequency: 230 V/50…60 Hz, CAT II
Artificial Hand: 220pF+511Ω
PE(selectable): 50µH||50Ω
Transient Limiter
Frequency Range: 150 kHz to 30 MHz
Transmission Loss: 10dB(+1.5/-0.5dB)
Connectors
Measurement Output: 50ΩBNC
Power Supply Socket for DUT: Schuko plug socket for:
HM6050-2D(DEVersion)
HM6050-2K(UKVersion)
HM6050-2S(USVersion)
Artificial Hand: 4mmbananasocket
Line Cord: Fixed
Miscellaneous
Operating Temperature: 10°C to 40 °C
Power Supply: HM6050-2D(DEVersion)
230 V ±10 %, 50…60 Hz
HM6050-2K(UKVersion)
230 V ±10 %, 50…60 Hz
HM6050-2S(USVersion)
115 V ±10 %, 50…60 Hz
Safety Class: SafetyclassI(IEC1010-1/VDE0411)
Dimensions(WxHxD): 285 x 125 x 380 mm
Weight: Approx. 6 kg
Technical Data