HM6050-2 Line Impedance Stabilization Network Technical Data / Insertion Loss HM6050-2K: UK Version HM6050-2S: US Version Key facts ❙❙ Single-phase V-network to measure line-conducted interferences from 10 kHz to 30 MHz (based on CISPR 161)) ❙❙ Selectable Transient Limiter ❙❙ Artificial Hand Connector PD 5210.8589.
Technical Data Line Impedance Stabilization Network HM6050-2 All data valid at 23 °C after 30 minutes warm-up. Frequency Range: 10 kHz to 30 MHz Impedance Characteristics: Max. Current: = 50 Ω || (50 µH + 5 Ω), Z Error <20% under terms of VDE 876T1 16A Line Voltage/Frequency: 230V/50…60Hz, CAT II Artificial Hand: 220 pF + 511 Ω PE (selectable): 50 µH || 50 Ω Transient Limiter Frequency Range: 150kHz to 30MHz Transmission Loss: 10 dB (+1.5/-0.
Insertion Loss 150kHz to 30MHz (typ.
frequency kHz HM6050-2 HM6050-2 HM6050-2 with limiter (valid for L1 and N measurements) without limiter “N” witout limiter “L1” dB dB (-10) dB dB (-10) dB dB (-10) 150 -11,8 -1,8 -11,5 -1,5 -11,5 -1,5 200 -11,2 -1,2 -11,2 -1,2 -11,2 -1,2 250 -10,9 -0,9 -10,9 -0,9 -11,0 -1,0 300 -10,7 -0,7 -10,8 -0,8 -10,8 -0,8 350 -10,6 -0,6 -10,7 -0,7 -10,7 -0,7 400 -10,6 -0,6 -10,6 -0,6 -10,6 -0,6 450 -10,5 -0,5 -10,5 -0,5 -10,5 -0,5 500 -10,5 -0,5 -10,5 -0
Insertion Loss 9kHz to 150kHz (typ.
frequency kHz HM6050-2 HM6050-2 without limiter “N” without limiter “L1” dB dB 9 -18,1 -18,1 10 -16,9 -16,9 15 -15,1 -15,1 20 -13,0 -13,0 25 -11,4 -11,4 30 -9,9 -9,9 35 -8,7 -8,7 40 -7,8 -7,8 45 -6,7 -6,7 50 -6,1 -6,1 55 -5,6 -5,6 60 -5,0 -5,0 70 -4,1 -4,1 80 -3,4 -3,4 90 -2,9 -2,9 100 -2,5 -2,5 110 -2,3 -2,3 120 -2,1 -2,1 130 -1,8 -1,8 140 -1,6 -1,6 150 -1,5 -1,5 ficate_HM6050-2E/260310/ce · Subject to changes · © HAMEG Instruments GmbH®
© 2016 Rohde & Schwarz GmbH & Co. KG Mühldorfstr. 15, 81671 München, Germany Phone: +49 89 41 29 - 0 Fax: +49 89 41 29 12 164 E-mail: info@rohde-schwarz.com Internet: www.rohde-schwarz.com Customer Support: www.customersupport.rohde-schwarz.com Service: www.service.rohde-schwarz.com Subject to change – Data without tolerance limits is not binding. R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG. Trade names are trademarks of the owners. 5210.8589.