Datasheet

HM6050-2
HM6050-2K
(UK Version, 230 V)
HM6050-2S
(US Version, 115 V)
R Measurement of Line-conducted Interferences
within the Range from 9 kHz…30 MHz (CISPR 16)
R Selectable Transient Limiter
R Artificial Hand Connector
Technical Specifications at 23 °C ±2 °C
Frequency Range: 9 kHz…30 MHz
Impedance Characteristics: Z = 50 Ω || (50 µH + 5 Ω),
Error <20 % under terms of VDE 876T1
Max. Current: 16 A
Line Voltage/Frequency: 230 V/50…60 Hz, CAT II
Artificial Hand: 220 pF + 511 Ω
PE (selectable): 50 µH || 50 Ω
Transient Limiter
Frequency Range: 150 kHz…30 MHz
Transmission Loss: 10 dB (+1.5/-0.5 dB)
Connectors
Measurement Output: 50 Ω BNC
Power Supply Socket for DUT: Standard German (UK, US) wall outlets
Artificial Hand: 4 mm banana socket
Line Cord: fixed
Miscellaneous
Operating Temperature: 10…40 °C
Power Supply: HM6050-2D (DE Version) 230 V ±10 %, 50…60 Hz
HM6050-2K (UK Version) 230 V ±10 %, 50…60 Hz
HM6050-2S (US Version) 115 V ±10 %, 50…60 Hz
Safety Class: Safety class I (IEC1010-1/VDE 0411)
Dimensions and Weight: 285 x 125 x 380 mm (W x H x D), approx. 6 kg
Line Impedance Stabilization Network
HM6050-2
Measurement
of Line-conducted
Interference: Fail
Measurement
of Line-conducted
Interference: Pass
HM6050-2E/140812 · C&E · Subject to change without notice · © HAMEG Instruments GmbH
®
· DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 8000 · Fax +49 (0) 6182 800100 · www.hameg.com · info@hameg.com