HMO3000_bro_de-en_3607-0146-3X_v0200.indd 1 Product Brochure | 02.00 Test & Measurement R&S®HMO3000 Series Mixed Signal Oscilloscopes 300/400/500 MHz Bandwidth 29.02.
Precise signal analysis Intelligent user interface FFT Quick view 4 Gsamples/s sampling rate 8 Msamples memory To optimize the screen display the instrument shows and hides menus Superb FFT functionality At the push of a button the 16 most important values of the measured signal are permanently updated and displayed Product of the Year 2014 HMO3000 Winner in category Test & Measurement Setup Intuitive, multi-lingual user menu Help Context-sensitive help Math Wide range of programmable math func
At a glance Systems that are constantly becoming faster and more complex lead to ever higher demands on the required measurement technology. The oscilloscope series R&S®HMO3000 offers the solution for current requirements in regards to bandwidth, sampling rate and memory depth. Its bandwidth of up to 500 MHz allows to set a new milestone in the development of high-performance mixedsignal oscilloscopes at an attractive price.
Key facts Superior hardware-based acquisition for precise measurement results ❙❙ 4 Gsample/s sampling rate, 8 Msample memory depth ❙❙ High vertical sensitivity down to 1 mV/div ❙❙ Low-noise measurement due to state-of-the-art A/D converter ❙❙ High acquisition rate to identify signal faults ❙❙ Segmented memory and manually adjustable memory depth Versatile measurement functions and fast results ❙❙ Wide selection of automatic measurement functions ❙❙ QuickView: key results at the push of a button ❙❙ Mask test
300 MHz, 400 MHz, 500 MHz Should your requirements change, then so does the R&S®HMO3000, as the 300 MHz models can be extended to 400 MHz and 500 MHz bandwidth via software upgrades whenever required. This is done with option upgrade vouchers available at your dealer.
Always a MSO The mixed signal functionality is always included in the R&S®HMO3000 series with no software option being necessary to unlock it. 6 Rohde & Schwarz R&S®HMO3000 Series HMO3000_bro_de-en_3607-0146-3X_v0200.indd 6 29.02.
Rohde & Schwarz is offering the R&S®HMO3000 series exclusively as a mixed-signal oscilloscope. The great advantages of these instruments are best illustrated by taking a look at how ADCs (Analog Digital Converter) or DACs (Digital Analog Converter) are integrated. Optional: Logic probe R&S®HO3508 These transformer modules include an analog signal on the one side and a digital signal on the other side.
Serial Bus Analysis I2C, SPI, CAN or LIN – in terms of interaction with the outside world for embedded systems, it is safe to say that these are the most commonly used communication protocols. The R&S®HMO3000 series by Rohde & Schwarz offers you hardware-accelerated signal triggering and decoding for all of these protocols.
Segmented Memory The segmented memory option R&S®HOO14 enables you to divide the available acquisition memory of the R&S®HMO3000 into up to 1000 segments. This procedure allows sampling rates of 200 000 Wfm/s, which makes it possible to capture rare anomalies occurring during many short events in quick succession. Segmentation can be applied on the acquisition of analog and digital channels as well as onto the decoding of serial busses.
Digital Voltmeter (DVM) The three-digit digital voltmeter is also a standard feature which makes the work of service technicians in particular easier. Voltage measurements can be performed simultaneously for all analog channels. Integrated into a single compact device it allows you to keep your workplace tidy.
Frequency Analysis Due to the outstanding FFT functionality of the R&S®HMO series oscilloscopes signals can also be analysed in the frequency domain with up to 65,536 points. Additional practical tools such as cursor measurement as well as peak-detect functions are also available. They allow engineers to complete their analysis significantly faster, also in the frequency domain.
R&S®HMO3002 series 2-channel mixed signal oscilloscope R&S®HMO3004 series 4-channel mixed signal oscilloscope R&S®HMO3032, R&S®HMO3034: 300 MHz R&S®HMO3042, R&S®HMO3044: 400 MHz R&S®HMO3052, R&S®HMO3054: 500 MHz Rise time (calculated, 10% to 90%) < 0.875 ns Trigger level setting R&S®HMO305x < 0.
Min. signal amplitude 0.8 Div Trigger level range (seperately ±8 Div (from center of screen) adjustable with different sources) external ±5.
Cursor measurements Quick measurements (QUICKVIEW) Marker voltage (V1, V2, ∆V), time (t1, t2, ∆t, 1/∆t), ratio X, ratio Y, pulse and edge count (pos/neg), peak values (Vpp, Vp+, Vp-), mean/RMS/standard deviation, duty cycle (pos/neg), burst width, rise/fall time (80%, 90%), ratio marker, crest factor voltage (Vpp, Vp+, Vp-, Vrms), frequency, period (predefined), 6 additional measure-ment functions (see automatic measurement functions) freely selectable plus statistics up to 8 freely positionable markers
Recommended Accessories R&S®HO720 R&S®HO740 HZO20 HZO30 HZ115 USB-device/RS-232 dualinterface card IEEE-488 (GPIB) interface card, galvanically isolated High voltage probe 1000:1 (400 MHz, 1000 Vrms) 1 GHz active probe (0.9 pF, 1 MΩ) Differential Probe 100:1/1000:1 R&S®HO3508 HZO40 HZO41 8 channel logic probe (350 MHz, 4 pF) Active differential probe 200 MHz (10:1, 3.
© 2015 Rohde & Schwarz GmbH & Co. KG Mühldorfstr. 15, 81671 München, Germany Phone: +49 89 41 29 - 0 Fax: +49 89 41 29 12 164 E-mail: info@rohde-schwarz.com Internet: www.rohde-schwarz.com Subject to change – Data without tolerance limits is not binding. R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG. Trade names are trademarks of the owners. 01/16 HMO3000_bro_de-en_3607-0146-3X_v0200.indd 16 PD 3607.0146.32 V 02.00 PDP1 en 3607014632 29.02.