Instructions
Table Of Contents
- Cover
- Contents
- 1 For Your Safety
- 2 Getting Started
- 3 Waveform Setup
- 3.1 Connecting Probes
- 3.2 Vertical Setup
- 3.3 Horizontal Setup
- 3.4 Acquisition Control
- 3.5 Roll Mode
- 3.6 Trigger
- 3.6.1 General Trigger Settings
- 3.6.2 Edge Trigger
- 3.6.3 Glitch Trigger
- 3.6.4 Width Trigger
- 3.6.5 Video/TV Trigger
- 3.6.6 External Trigger (R&S RTH1002)
- 3.6.7 Pattern Trigger (R&S RTH-K19)
- 3.6.8 State Trigger (R&S RTH-K19)
- 3.6.9 Runt Trigger (R&S RTH-K19)
- 3.6.10 Slew Rate Trigger (R&S RTH-K19)
- 3.6.11 Data2Clock Trigger (R&S RTH-K19)
- 3.6.12 Serial Pattern Trigger (R&S RTH-K19)
- 3.6.13 Timeout Trigger (R&S RTH-K19)
- 3.6.14 Interval Trigger (R&S RTH-K19)
- 3.6.15 Window Trigger (R&S RTH-K19)
- 3.6.16 Protocol Trigger (R&S RTH-K1, -K2, -K3, -K9 and -K10)
- 4 Waveform Analysis
- 5 Mask Testing
- 6 Spectrum Analysis
- 6.1 FFT Mode
- 6.2 Spectrum Mode (Option R&S RTH-K18)
- 6.3 Harmonics Measurement (Option R&S RTH-K34)
- 7 Multimeter Measurements
- 8 Data Logging
- 9 Protocol Analysis
- 10 Logic Analyzer (R&S RTH-B1 MSO)
- 11 Frequency Counter (R&S RTH-K33)
- 12 Documenting Results
- 13 General Instrument Setup
- 14 Network Connections
- 15 Remote Control Commands
- 15.1 Conventions used in Command Description
- 15.2 Mode
- 15.3 Waveform Setup
- 15.3.1 Automatic Setup
- 15.3.2 Vertical Setup
- 15.3.3 Horizontal Setup
- 15.3.4 Acquisition Control
- 15.3.5 Trigger
- 15.3.5.1 General Trigger Settings
- 15.3.5.2 Edge Trigger
- 15.3.5.3 Glitch Trigger
- 15.3.5.4 Width Trigger
- 15.3.5.5 Video/TV Trigger
- 15.3.5.6 External Trigger (R&S RTH1002)
- 15.3.5.7 Pattern Trigger (R&S RTH-K19)
- 15.3.5.8 State Trigger (R&S RTH-K19)
- 15.3.5.9 Runt Trigger (R&S RTH-K19)
- 15.3.5.10 Slew Rate Trigger (R&S RTH-K19)
- 15.3.5.11 Data2Clock Trigger (R&S RTH-K19)
- 15.3.5.12 Serial Pattern Trigger (R&S RTH-K19)
- 15.3.5.13 Timeout Trigger (R&S RTH-K19)
- 15.3.5.14 Interval Trigger (R&S RTH-K19)
- 15.3.5.15 Window Trigger (R&S RTH-K19)
- 15.4 Waveform Analysis
- 15.5 Mask Testing
- 15.6 Spectrum Analysis
- 15.7 Digital Multimeter (R&S RTH1002)
- 15.8 Voltmeter (R&S RTH1004)
- 15.9 Counter Mode (R&S RTH-K33)
- 15.10 Data Logging
- 15.11 Protocol Analysis
- 15.12 Logic Analyzer (R&S RTH-B1 MSO)
- 15.13 Documenting Results
- 15.14 General Instrument Setup
- 15.15 WLAN Connection (Option R&S RTH-K200/200US)
- 15.16 User Scripting (R&S RTH-K38)
- Annex
- List of Commands
Remote Control Commands
R&S
®
Scope Rider RTH
496User Manual 1326.1578.02 ─ 15
Example: See Example "Saving history data of channel 1, without time val-
ues" on page 494.
EXPort:WAVeform:SAVE
Saves the waveform(s) to the file specified with EXPort:WAVeform:NAME.
Example: See Example "Saving a single waveform with time values"
on page 493.
Usage: Event
15.13.2 Transfer of Waveform Data
Data conversion of integer values if FORMat:DATA INT,16 is used
To convert INT16 data to physical quantities, e.g. voltages, use the following formulas:
PhysicalQuantity = ( Value_ADC * ConversionFactor ) + VerticalOffset
eff
ConversionFactor = VerticalScale * VerticalDivisionCount / NofQuantisationLevels
VerticalOffset
eff
= VerticalOffset – VerticalPosition * VerticalScale
Table 15-1: Data conversion example
VerticalScale 0.05 V/div
VerticalOffset 0.1 V
VerticalPosition 1 div
NofQuantisationLevels 255 * 256
VerticalDivisionCount 8
Value_ADC -61
ConversionFactor 0.05 * 8 / (255 * 256) = 0.000006127451 V
VerticalOffset
eff
0.1 - 1 * 0.05 = 0.05 V
Voltage (-61 * 0.000006127451 V) + 0.05 V = -0.32 mV
The values are read with CHANnel<m>:DATA[:VALues]?.
To get the vertical scale, position and offset, you can use the appropriate commands:
●
CHANnel<m>:SCALe on page 304
●
CHANnel<m>:POSition on page 306
●
CHANnel<m>:OFFSet on page 306
You can finde these values also in the data export file, see Chapter 15.13.1, "Export of
Waveform Data to File", on page 493.
Documenting Results