Instructions

Table Of Contents
Fernsteuerbefehle
R&S
®
Scope Rider RTH
449Bedienhandbuch 1326.1578.03 ─ 10
Parameter:
<Parity> NONE | ODD | EVEN
NONE
No parity bit is used.
ODD
The parity bit is set to "1" if the number of data bits set to "1" is
even.
EVEN
The parity bit is set to "1" if the number of data bits set to "1" is
odd.
*RST: NONE
BUS:UART:SBIT <StopBits>
Sets the number of stop bits: 1 or 1.5 or 2 stop bits are possible.
Parameter:
<StopBits> B1 | B15 | B2
*RST: B1
BUS:UART:ORDer <BitOrder>
Defines if a word starts with MSB (most significant bit) or LSB (least significant bit).
The display of the decoded signal considers this setting, results are displayed in the
specified order.
Parameter:
<BitOrder> LSBF | MSBF
*RST: MSBF
BUS:UART:FRAMemode <FrameMode>
IDLE defines frames of several words in the data stream, which are defined by a time-
out between a stop bit and the next start bit. Enter the minimum timeout between two
frames using BUS:UART:TOUT.
Parameter:
<FrameMode> NONE | IDLE
*RST: NONE
BUS:UART:TOUT <IdleTime>
Sets the minimum timeout between two frames if BUS:UART:FRAMemode is set to
IDLE.