Instructions

Table Of Contents
Fernsteuerbefehle
R&S
®
Scope Rider RTH
388Bedienhandbuch 1326.1578.03 ─ 10
Parameter:
<Unit> C | F | K
METer:SENSe:TEMPerature:TRANsductor:RTD:TYPE <Unit>
Sets the adapter type for temperature measurements.
Parameter:
<Unit> PT100 | PT500
15.7.3 Relative Messungen
Setzen Sie zur Durchführung relativer Messungen den relevanten
METer:SENSe:<function>:NULL:STATe-Befehl auf ON. Der Referenzwert ist stan-
dardmäßig 0. Alternativ können Sie METer<m>:SENSe:RELative:STATe verwen-
den.
Sie können den Referenzwert mit dem Befehl
METer:SENSe:<function>:NULL:VALue ändern.
METer:SENSe:CAPacitance:NULL:STATe....................................................................... 388
METer:SENSe:CURRent:AC:NULL:STATe.......................................................................388
METer:SENSe:CURRent:DC:NULL:STATe.......................................................................388
METer:SENSe:RESistance:NULL:STATe......................................................................... 388
METer:SENSe:TEMPerature:NULL:STATe.......................................................................388
METer:SENSe:VOLTage:AC:NULL:STATe.......................................................................388
METer:SENSe:VOLTage:DC:NULL:STATe.......................................................................388
METer<m>:SENSe:NULL:STATe.................................................................................... 389
METer<m>:SENSe:RELative:STATe................................................................................389
METer:SENSe:CAPacitance:NULL:VALue........................................................................389
METer:SENSe:CURRent:AC:NULL:VALue....................................................................... 389
METer:SENSe:CURRent:DC:NULL:VALue.......................................................................389
METer:SENSe:VOLTage:AC:NULL:VALue....................................................................... 389
METer:SENSe:VOLTage:DC:NULL:VALue.......................................................................389
METer:SENSe:RESistance:NULL:VALue......................................................................... 390
METer:SENSe:TEMPerature:NULL:VALue....................................................................... 390
METer<m>:SENSe:NULL:VALU......................................................................................390
METer:SENSe:CAPacitance:NULL:STATe <State>
METer:SENSe:CURRent:AC:NULL:STATe <State>
METer:SENSe:CURRent:DC:NULL:STATe <State>
METer:SENSe:RESistance:NULL:STATe <State>
METer:SENSe:TEMPerature:NULL:STATe <State>
METer:SENSe:VOLTage:AC:NULL:STATe <State>
METer:SENSe:VOLTage:DC:NULL:STATe <State>
Enables or disables the relative measurement. The reference value is defined using
the appropriate METer:SENSe:<function>:NULL:VALue command.
Digitalmultimeter (R&S RTH1002)