351Bedienhandbuch 1326.1578.03 ─ 10
Parameter:
<State> ON | OFF
*RST: OFF
MASK:CHANnel<m>:PROPerties:XWIDth <WidthX>
Changes the width of the selected mask in horizontal direction.
Suffix:
<m>
.
1|2|5 (RTH1002) , 1..5 (RTH1004)
Parameter:
<WidthX> Bereich: 0 bis 10
Inkrement: 0.01
*RST: 0.05
Std-einheit: div
MASK:CHANnel<m>:PROPerties:YWIDth <WidthY>
Changes the width of the selected mask in vertical direction.
Suffix:
<m>
.
1|2|5 (RTH1002) , 1..5 (RTH1004)
Parameter:
<WidthY> Bereich: 0 bis 8
Inkrement: 0.01
*RST: 0.1
Std-einheit: div
MASK:CHANnel<m>:CREatemask
Creates a mask from the envelope waveform of the selected waveform with the defi-
ned width in x and y direction.
Suffix:
<m>
.
1|2|5 (RTH1002) , 1..5 (RTH1004)
Verwendung: Ereignis
15.5.2 Maskentest
MASK:ONViolation[:SELection]....................................................................................... 352
MASK:RST....................................................................................................................352
MASK[:TESTstate]?....................................................................................................... 352
MASK:CHANnel<m>:RESult:FAIL:PERCentage?..............................................................352
MASK:CHANnel<m>:RESult:FAIL[:COUNt]?.....................................................................353
MASK:CHANnel<m>:RESult:PASS:PERCentage?............................................................ 353
MASK:CHANnel<m>:RESult:PASS[:COUNt]?...................................................................353
Maskentests