Instructions

Table Of Contents
Fernsteuerbefehle
R&S
®
Scope Rider RTH
344Bedienhandbuch 1326.1578.03 ─ 10
Suffix:
<m>
.
1..2
Defines the measurement index. Two simultaneous cursor mea-
surements can be performed.
Rückgabewerte:
<ResultLimit> INSide | OVERflow | UNDerflow | OVUNflow
*RST: INSide
Verwendung: Nur Abfrage
15.4.4 Mathematische Messkurven
15.4.4.1 Math-Einstellungen
CALCulate:MATH:STATe................................................................................................344
CALCulate:MATH[:EXPRession][:DEFine]........................................................................ 344
CALCulate:MATH:VERTical:SCALe.................................................................................345
CALCulate:MATH:VERTical:RANGe................................................................................ 345
CALCulate:MATH:VERTical:POSition.............................................................................. 345
CALCulate:MATH:STATe <State>
Enables or disables the math channel.
Parameter:
<State> ON | OFF
Verwendung: SCPI-konform
CALCulate:MATH[:EXPRession][:DEFine] <ExprDefinition>
Sets the operation to calculate a math waveform.
Parameter:
<ExprDefinition> String that defines the operation. x is the channel number of
source 1, y the channel number of source 2.
Addition: 'Cx+Cy'
Subtraction: 'Cx-Cy'
Multiplication: 'Cx*Cy'
Inverse: '-Cx'
Absolute value: 'Abs(Cx)'
Square: 'Pow(Cx)'
Beispiel:
CALC:MATH:EXPR:DEF 'C1-C2'
Subtracts the values of CH2 from the values of CH1.
CALC:MATH:EXPR:DEF 'Pow(C1)'
Squares the values of CH1.
Verwendung: SCPI-konform
Messkurvenanalyse