Instructions

Table Of Contents
Fernsteuerbefehle
R&S
®
Scope Rider RTH
326Bedienhandbuch 1326.1578.03 ─ 10
Parameter:
<Condition> ANY | LONGer | SHORter | EQUal | NEQual | WITHin | OUTSide
ANY
Triggers on all runts fulfilling the level condition, without time
limitation.
LONGer | SHORter
Defines a minimum time during which the signals match the pat-
tern definition. The minimum time is defined by
EQUal | NEQual
Triggers on pulses equal or not equal a given runt width that is
set using TRIGger:RUNT:WIDTh. In addition, a tolerance can
be set around the specified width using TRIGger:RUNT:DELTa
.
WITHin | OUTSide
Triggers on pulses inside or outside a given range. The range is
set using ... and ....
*RST:
LONGer
TRIGger:RUNT:WIDTh <Duration>
Sets the width for comparison ranges EQUal, UNEQual, SHORter, and LONGer.
See TRIGger:WIDTh:RANGe.
Parameter:
<Duration> Bereich: 800E-12 bis 10000
Inkrement: 100E-9
*RST: 5E-9
Std-einheit: s
TRIGger:RUNT:DELTa <Tolerance>
Sets a range Δt to the specified width, which is defined using TRIGger:RUNT:WIDTh.
Parameter:
<Tolerance> Bereich: 0 bis 5000
Inkrement: 500E-12
*RST: 0
Std-einheit: s
TRIGger:RUNT:MINWidth <MinDuration>
Sets the lower time limit of the runt for comparisons WITHin and OUTSide.
Parameter:
<MinDuration> Bereich: 800E-12 bis 10000
Inkrement: 100E-9
*RST: 5E-9
Std-einheit: s
Grundeinstellungen