Instructions

Table Of Contents
Remote Control Commands
R&S
®
Scope Rider RTH
476User Manual 1326.1578.02 ─ 15
Return values:
<Data> Comma-separated list of integer values (N, D1, D2,…, DN). N is
the number of bytes in the frame, and D1…DN are the values of
the bytes.
Example:
BUS:LIN:FRAMe4:DATA?
<-- 4,118,39,71,123
Usage: Query only
BUS:LIN:FRAMe<m>:IDPValue?
Returns the value of the identifier parity bits of the selected frame.
Suffix:
<m>
.
*
Return values:
<IdentifierParity> Range: 0 to 3
*RST: 0
Usage: Query only
BUS:LIN:FRAMe<m>:IDSTate?
Returns the identifier state of the selected frame.
Suffix:
<m>
.
*
Return values:
<IdentifierState> OK | STERror | SPERror | PRERror | UVAL | NOEXists |
INSufficient
STERror: start error
SPERror: stop error
PRERror: parity error
UVAL: unexpected value
NOEXists: byte does not exist
INSufficient: the frame is not completely contained in the acqui-
sition. The decoded part of the frame is valid.
*RST: OK
Usage: Query only
BUS:LIN:FRAMe<m>:IDValue?
Returns the identifier value of the selected frame.
Suffix:
<m>
.
*
Protocol Analysis