Instructions

Table Of Contents
Remote Control Commands
R&S
®
Scope Rider RTH
381User Manual 1326.1578.02 ─ 15
Suffix:
<m>
.
1|2 (RTH1002) , 1..4 (RTH1004)
Return values:
<State> ON | OFF
ON
A limit violation occurred for at least one harmonic - the limit
check for the signal failed.
OFF
No limit violations occurred. The limit check was passed.
*RST: OFF
Usage: Query only
HARMonic:RESult<m>:NOHarmonics?
Returns the number of harmonics for which results are displayed. The maximum num-
ber of 64 harmonics may be restricted due to the HARMonic:LIMits:TYPE com-
mand.
Suffix:
<m>
.
1|2 (RTH1002) , 1..4 (RTH1004)
Return values:
<NoSelection> Range: 1 to 64
Increment: 1
*RST: 64
Usage: Query only
HARMonic:RESult<m>:NOResults?
Returns the number of results included in averaging or statistics calculations. Invalid
measurements are not included.
Suffix:
<m>
.
1|2 (RTH1002) , 1..4 (RTH1004)
Return values:
<NoResults> Range: 0 to 4000000000
Increment: 1
*RST: 0
Usage: Query only
HARMonic:RESult<m>:RMS:MAXimum?
HARMonic:RESult<m>:RMS:MINimum?
HARMonic:RESult<m>:RMS[:CURRent]?
Returns the currently calculated, minimum, or maximum root mean square of the
power in the entire signal, that is: for all harmonics and the fundamental frequency.
Spectrum Analysis