SPECtrum:CURSor<m>:FREQuency[:VALue] <Frequency>
Queries the frequency at the specified cursor.
Suffix:
<m>
.
1..2
Parameters:
<Frequency> Range: 0 to 500E+6
Increment: 10
*RST: 100E+6
Default unit: Hz
SPECtrum:CURSor<m>:FREQuency:DELTa?
Queries the difference between the measured frequencies at both cursors.
Suffix:
<m>
.
1..2
irrelevant
Return values:
<FrequencyDelta> Range: -500E+6 to 500E+6
Increment: 10
*RST: 300E+6
Default unit: Hz
Usage: Query only
SPECtrum:CURSor<m>:LEVel[:VALue]?
Queries the measured level at the specified cursor.
Suffix:
<m>
.
1..2
Return values:
<Level> Range: -260 to 260
Increment: 1
*RST: 0
Default unit: dB
Usage: Query only
SPECtrum:CURSor<m>:LEVel:DELTa?
Queries the difference in the measured levels for both cursors.
Suffix:
<m>
.
1..2
irrelevant