TRIGger:TV:CUSTom:LDURation <LineDuration>
Sets the duration of a single video line, the time between two successive sync pulses.
Parameters:
<LineDuration> Range: 5E-6 to 200E-6
Increment: 100E-9
*RST: 64E-6
Default unit: s
TRIGger:TV:CUSTom:SDURation
<SyncPulseDuration>
Sets the width of the sync pulse.
Parameters:
<SyncPulseDuration> Range: 100E-9 to 100E-6
Increment: 100E-9
*RST: 4.7E-6
Default unit: s
TRIGger:TV:CUSTom:SCANmode <ScanMode>
Sets the scanning system.
For details, see "Scan" on page 62.
Parameters:
<ScanMode> INTerlaced | PROGressive | SEGMented
*RST: INTerlaced
15.3.5.6 External Trigger (R&S RTH1002)
TRIGger:EXTernal:LEVel................................................................................................ 322
TRIGger:EXTernal:SLOPe.............................................................................................. 322
TRIGger:EXTernal:LEVel <Level>
Sets the trigger voltage level.
Parameters:
<Level> Range: -10 to 10
Increment: 1E-3
*RST: 0
Default unit: V
TRIGger:EXTernal:SLOPe <Slope>
Sets the edge direction for the trigger. You can trigger on the rising edge, the falling
edge, or riding and falling edges of the external signal.
Waveform Setup