Instructions
Table Of Contents
- Cover
- Contents
- 1 For Your Safety
- 2 Getting Started
- 3 Waveform Setup
- 3.1 Connecting Probes
- 3.2 Vertical Setup
- 3.3 Horizontal Setup
- 3.4 Acquisition Control
- 3.5 Roll Mode
- 3.6 Trigger
- 3.6.1 General Trigger Settings
- 3.6.2 Edge Trigger
- 3.6.3 Glitch Trigger
- 3.6.4 Width Trigger
- 3.6.5 Video/TV Trigger
- 3.6.6 External Trigger (R&S RTH1002)
- 3.6.7 Pattern Trigger (R&S RTH-K19)
- 3.6.8 State Trigger (R&S RTH-K19)
- 3.6.9 Runt Trigger (R&S RTH-K19)
- 3.6.10 Slew Rate Trigger (R&S RTH-K19)
- 3.6.11 Data2Clock Trigger (R&S RTH-K19)
- 3.6.12 Serial Pattern Trigger (R&S RTH-K19)
- 3.6.13 Timeout Trigger (R&S RTH-K19)
- 3.6.14 Interval Trigger (R&S RTH-K19)
- 3.6.15 Window Trigger (R&S RTH-K19)
- 3.6.16 Protocol Trigger (R&S RTH-K1, -K2, -K3, -K9 and -K10)
- 4 Waveform Analysis
- 5 Mask Testing
- 6 Spectrum Analysis
- 6.1 FFT Mode
- 6.2 Spectrum Mode (Option R&S RTH-K18)
- 6.3 Harmonics Measurement (Option R&S RTH-K34)
- 7 Multimeter Measurements
- 8 Data Logging
- 9 Protocol Analysis
- 10 Logic Analyzer (R&S RTH-B1 MSO)
- 11 Frequency Counter (R&S RTH-K33)
- 12 Documenting Results
- 13 General Instrument Setup
- 14 Network Connections
- 15 Remote Control Commands
- 15.1 Conventions used in Command Description
- 15.2 Mode
- 15.3 Waveform Setup
- 15.3.1 Automatic Setup
- 15.3.2 Vertical Setup
- 15.3.3 Horizontal Setup
- 15.3.4 Acquisition Control
- 15.3.5 Trigger
- 15.3.5.1 General Trigger Settings
- 15.3.5.2 Edge Trigger
- 15.3.5.3 Glitch Trigger
- 15.3.5.4 Width Trigger
- 15.3.5.5 Video/TV Trigger
- 15.3.5.6 External Trigger (R&S RTH1002)
- 15.3.5.7 Pattern Trigger (R&S RTH-K19)
- 15.3.5.8 State Trigger (R&S RTH-K19)
- 15.3.5.9 Runt Trigger (R&S RTH-K19)
- 15.3.5.10 Slew Rate Trigger (R&S RTH-K19)
- 15.3.5.11 Data2Clock Trigger (R&S RTH-K19)
- 15.3.5.12 Serial Pattern Trigger (R&S RTH-K19)
- 15.3.5.13 Timeout Trigger (R&S RTH-K19)
- 15.3.5.14 Interval Trigger (R&S RTH-K19)
- 15.3.5.15 Window Trigger (R&S RTH-K19)
- 15.4 Waveform Analysis
- 15.5 Mask Testing
- 15.6 Spectrum Analysis
- 15.7 Digital Multimeter (R&S RTH1002)
- 15.8 Voltmeter (R&S RTH1004)
- 15.9 Counter Mode (R&S RTH-K33)
- 15.10 Data Logging
- 15.11 Protocol Analysis
- 15.12 Logic Analyzer (R&S RTH-B1 MSO)
- 15.13 Documenting Results
- 15.14 General Instrument Setup
- 15.15 WLAN Connection (Option R&S RTH-K200/200US)
- 15.16 User Scripting (R&S RTH-K38)
- Annex
- List of Commands
Remote Control Commands
R&S
®
Scope Rider RTH
303User Manual 1326.1578.02 ─ 15
15.3 Waveform Setup
● Automatic Setup....................................................................................................303
● Vertical Setup........................................................................................................303
● Horizontal Setup....................................................................................................309
● Acquisition Control................................................................................................ 310
● Trigger...................................................................................................................313
15.3.1 Automatic Setup
AUToscale
Performs an autoset in scope mode.
Usage:
Event
15.3.2 Vertical Setup
The channel suffix <m> selects the channel for which the command is executed. The
number of channels depends on the instrument type. The R&S RTH1004 has 4 chan-
nels, the suffix values are 1 | 2 | 3 | 4. The R&S RTH1002 has 2 channels, the suffix
values are 1 | 2.
Make sure to set the attenuation factor on the instrument according to the probe being
used. Otherwise, the measurement results do not reflect the actual voltage level, and
you might misjudge the actual risk.
CHANnel<m>:STATe...................................................................................................... 303
CHANnel<m>:SCALe..................................................................................................... 304
CHANnel<m>:RANGe.................................................................................................... 304
CHANnel<m>:PROBe.................................................................................................... 304
PROBe<m>:SETup:ATTenuation:MANual.........................................................................305
PROBe<m>:SETup:ATTenuation:UNIT.............................................................................305
CHANnel<m>:POSition...................................................................................................306
CHANnel<m>:OFFSet.................................................................................................... 306
CHANnel<m>:COUPling.................................................................................................306
CHANnel<m>:BANDwidth...............................................................................................307
CHANnel<m>:POLarity...................................................................................................307
CHANnel<m>:DESKew.................................................................................................. 307
CHANnel<m>:THReshold:TECHnology............................................................................308
CHANnel<m>:THReshold:USER..................................................................................... 308
CHANnel<m>:THReshold:THReshold?............................................................................ 308
CHANnel<m>:THReshold:FINDlevel................................................................................ 309
CHANnel<m>:STATe <State>
Switches the channel signal on or off.
Waveform Setup