Instructions
Table Of Contents
- Cover
- Contents
- 1 For Your Safety
- 2 Getting Started
- 3 Waveform Setup
- 3.1 Connecting Probes
- 3.2 Vertical Setup
- 3.3 Horizontal Setup
- 3.4 Acquisition Control
- 3.5 Roll Mode
- 3.6 Trigger
- 3.6.1 General Trigger Settings
- 3.6.2 Edge Trigger
- 3.6.3 Glitch Trigger
- 3.6.4 Width Trigger
- 3.6.5 Video/TV Trigger
- 3.6.6 External Trigger (R&S RTH1002)
- 3.6.7 Pattern Trigger (R&S RTH-K19)
- 3.6.8 State Trigger (R&S RTH-K19)
- 3.6.9 Runt Trigger (R&S RTH-K19)
- 3.6.10 Slew Rate Trigger (R&S RTH-K19)
- 3.6.11 Data2Clock Trigger (R&S RTH-K19)
- 3.6.12 Serial Pattern Trigger (R&S RTH-K19)
- 3.6.13 Timeout Trigger (R&S RTH-K19)
- 3.6.14 Interval Trigger (R&S RTH-K19)
- 3.6.15 Window Trigger (R&S RTH-K19)
- 3.6.16 Protocol Trigger (R&S RTH-K1, -K2, -K3, -K9 and -K10)
- 4 Waveform Analysis
- 5 Mask Testing
- 6 Spectrum Analysis
- 6.1 FFT Mode
- 6.2 Spectrum Mode (Option R&S RTH-K18)
- 6.3 Harmonics Measurement (Option R&S RTH-K34)
- 7 Multimeter Measurements
- 8 Data Logging
- 9 Protocol Analysis
- 10 Logic Analyzer (R&S RTH-B1 MSO)
- 11 Frequency Counter (R&S RTH-K33)
- 12 Documenting Results
- 13 General Instrument Setup
- 14 Network Connections
- 15 Remote Control Commands
- 15.1 Conventions used in Command Description
- 15.2 Mode
- 15.3 Waveform Setup
- 15.3.1 Automatic Setup
- 15.3.2 Vertical Setup
- 15.3.3 Horizontal Setup
- 15.3.4 Acquisition Control
- 15.3.5 Trigger
- 15.3.5.1 General Trigger Settings
- 15.3.5.2 Edge Trigger
- 15.3.5.3 Glitch Trigger
- 15.3.5.4 Width Trigger
- 15.3.5.5 Video/TV Trigger
- 15.3.5.6 External Trigger (R&S RTH1002)
- 15.3.5.7 Pattern Trigger (R&S RTH-K19)
- 15.3.5.8 State Trigger (R&S RTH-K19)
- 15.3.5.9 Runt Trigger (R&S RTH-K19)
- 15.3.5.10 Slew Rate Trigger (R&S RTH-K19)
- 15.3.5.11 Data2Clock Trigger (R&S RTH-K19)
- 15.3.5.12 Serial Pattern Trigger (R&S RTH-K19)
- 15.3.5.13 Timeout Trigger (R&S RTH-K19)
- 15.3.5.14 Interval Trigger (R&S RTH-K19)
- 15.3.5.15 Window Trigger (R&S RTH-K19)
- 15.4 Waveform Analysis
- 15.5 Mask Testing
- 15.6 Spectrum Analysis
- 15.7 Digital Multimeter (R&S RTH1002)
- 15.8 Voltmeter (R&S RTH1004)
- 15.9 Counter Mode (R&S RTH-K33)
- 15.10 Data Logging
- 15.11 Protocol Analysis
- 15.12 Logic Analyzer (R&S RTH-B1 MSO)
- 15.13 Documenting Results
- 15.14 General Instrument Setup
- 15.15 WLAN Connection (Option R&S RTH-K200/200US)
- 15.16 User Scripting (R&S RTH-K38)
- Annex
- List of Commands
Getting Started
R&S
®
Scope Rider RTH
30User Manual 1326.1578.02 ─ 15
2.4.1.3 Using Front Panel Keys
For an overview of the front panel keys, see Figure 2-3
Key Press shortly Press and hold
[AUTOSET] analyses the active channels,
adjusts the instrument settings, and displays
stable waveforms.
[PRESET] sets the instrument to the default
factory state.
[MEAS] starts or stops the last configured auto-
matic measurements.
Opens or closes the "Meas"
dialog to configure the mea-
surements.
[ZOOM] enables or disables the zoom with the
last configuration.
If the zoom is on but not in focus, pressing the
key focuses the zoom.
Opens or closes the "Zoom"
dialog to configure the zoom
scale and position.
[CURSOR] starts or stops the last configured
cursor measurement.
If the cursor is on but not in focus, pressing the
key sets the focus to the first cursor line.
Opens or closes the "Cursor"
dialog to configure the mea-
surement.
[MATH] switches the math waveform on or off. Opens or closes the "Math"
dialog to configure the math
waveform.
Requires logic analyzer option R&S RTH-B1
(MSO).
The effect depends on the state of digital chan-
nels:
If the all digital channels are off, the key
switches them on and sets the focus.
If the digital channels are on but not in focus,
the key sets the focus.
If the focus is on digital channels, the key
switches them off.
Opens or closes the "Logic"
dialog to configure digital chan-
nels.
Activates or deactivates the serial bus.
Requires at least one serial triggering and
decoding option. Available options are listed in
the data sheet.
Opens or closes the "Bus" dia-
log to configure serial proto-
cols.
[SHIFT] opens a dialog to save and load instru-
ment settings.
Press and hold for 2 seconds
to disable or enable the touch-
screen.
If a dialog or menu is open, [BACK] closes it. If the menu is closed, the key tog-
gles the focus between focused element in the diagram and the Menu button.
Operating Basics